Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May;49(5):1288-1297.
doi: 10.1007/s10439-020-02650-6. Epub 2020 Oct 22.

Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics

Affiliations

Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics

Paris Vakiel et al. Ann Biomed Eng. 2021 May.

Erratum in

Abstract

Understanding stresses within the knee joint is central to understanding knee function, and the etiology and progression of degenerative joint diseases such as post-traumatic osteoarthritis. In this study, in vivo gait kinematics of four ovine subjects were recorded using a highly accurate Instrumented Spatial Linkage (ISL) as each subject walked on a standard treadmill. The subjects were then sacrificed, and the right hind limbs removed. Ten purpose-built Fibre Bragg Grating (FBG) sensors were positioned within each stifle joint and used to measured contact stresses on the articulating surface of the tibial plateau as the recorded gait was replicated using a 6-degrees-of-freedom parallel robotic system. This study provides the first accurate, direct measurement of stress in a joint during in vivo gait replication. It was hypothesized that the results would indicate a direct link between gait kinematics and measured stress values. Contrary to this expectation no direct link was found between individualistic differences in kinematics and differences in stress magnitudes. This finding highlights the complex multifactorial nature of stress magnitudes and distribution patterns across articular joints. The results also indicate that stress magnitudes within the knee joint are highly position dependent with magnitudes varying substantially between points only a few mm apart.

Keywords: Biomechanics; FBG sensors; Fibre optic sensors; Mechanical stress.

PubMed Disclaimer

References

    1. Adeeb, S. M., E. Y. SayedAhmed, J. Matyas, D. A. Hart, C. B. Frank, and N. G. Shrive. Congruency effects on load bearing in diarthrodial joints. Comput. Method. Biomec. 7:147–157, 2004. - DOI
    1. Andriacchi, T. P., P. L. Briant, S. L. Bevill, and S. Koo. Rotational changes at the knee after ACL injury cause cartilage thinning. Clin. Orthop. Relat. Res. 442:39–44, 2006. - DOI
    1. Andriacchi, T. P., A. Mündermann, R. L. Smith, E. J. Alexander, C. O. Dyrby, and S. Koo. A framework for the in vivo pathomechanics of osteoarthritis at the knee. Ann. Biomed. Eng. 32:447–457, 2004. - DOI
    1. Atarod, M., J. M. Rosvold, C. B. Frank, and N. G. Shrive. A novel testing platform for assessing knee joint mechanics: a parallel robotic system combined with an instrumented spatial linkage. Ann. Biomed. Eng. 42:1121–1132, 2014. - DOI
    1. Benoit, D. L., D. K. Ramsey, M. Lamontagne, L. Xu, P. Wretenberg, and P. Renström. Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. Gait Posture 24:152–164, 2006. - DOI

LinkOut - more resources