Viability criteria assessment during liver machine perfusion
- PMID: 33106683
- DOI: 10.1038/s41587-020-0720-z
Viability criteria assessment during liver machine perfusion
Comment on
-
An integrated perfusion machine preserves injured human livers for 1 week.Nat Biotechnol. 2020 Feb;38(2):189-198. doi: 10.1038/s41587-019-0374-x. Epub 2020 Jan 13. Nat Biotechnol. 2020. PMID: 31932726 Free PMC article.
References
-
- Mergental, H., Stephenson, B. T. F., Laing, R. W., Kirkham, A. J., Neil, D. A. H. & Wallace, L. L. et al. Development of clinical criteria for functional assessment to predict primary nonfunction of high-risk livers using normothermic machine perfusion. Liver Transpl. 24, 1453–1469 (2018). - DOI - PMC
-
- Cardini, B. et al. Clinical implementation of prolonged liver preservation and monitoring through normothermic machine perfusion in liver transplantation. Transplantation 104, 1917–1928 (2020).
-
- van Leeuwen, O. B., de Vries, Y., Fujiyoshi, M., Nijsten, M. W. N., Ubbink, R. & Pelgrim, G. J. et al. Transplantation of high-risk donor livers after ex situ resuscitation and assessment using combined hypo- and normothermic machine perfusion: a prospective clinical trial. Ann. Surg. 270, 906–914 (2019). - DOI