Intracardiac echocardiography guided nonocclusive balloon cryothermal applications to achieve antral isolation during pulmonary vein isolation
- PMID: 33106958
- DOI: 10.1007/s10840-020-00905-9
Intracardiac echocardiography guided nonocclusive balloon cryothermal applications to achieve antral isolation during pulmonary vein isolation
Abstract
Objective: Ablation for atrial fibrillation (AF) requires electrical isolation of the pulmonary veins (PV) by wide-area circumferential PV antral isolation (PVAI). Cryoballoon ablation delivers cryoenergy circumferentially after occlusion of the PV by the cryoballoon; thus, it is likely that the level of isolation, determined by adequate balloon-tissue contact, depends on PV anatomy. We sought to examine the need for nonocclusive segmental cryoballoon ablation in achieving antral isolation, describe methods of accurate visualization of the cryoballoon using intracardiac echocardiography (ICE), and provide data on biophysical characteristics of an effective nonocclusive cryothermal lesion.
Methods: Forty consecutive patients undergoing catheter ablation with a second-generation 28-mm cryoballoon and electroanatomic mapping (EAM) were included. Balloon was visualized with ICE, and its location was registered in EAM using available technology (CARTOSOUND, Biosense Webster). Need for delivery of nonocclusive lesions was based on level of isolation post occlusive lesions.
Results: Nonocclusive lesions to PVAI was required in 26 of 40 patients (65%) or 46 out of 148 veins (31%). Left PVs > 19.4 ± 2.9 mm, right superior PV > 20.2 ± 4.7mm, funnel-shaped PVs, and right PVs not converging to a carina were more likely to require nonocclusive lesions to achieve an antral level of isolation. Projection of balloon contour on EAM using CARTOSOUND successfully predicted level of isolation by voltage mapping.
Conclusion: Nonocclusive cryoballoon applications are commonly required to achieve antral isolation. Use of ICE can be helpful in determining the accurate location of the balloon and in predicting the level of isolation by voltage map.
Keywords: Atrial fibrillation; Catheter ablation; Cryoablation; Cryoballoon; Posterior wall isolation; Pulmonary vein isolation.
© 2020. Springer Science+Business Media, LLC, part of Springer Nature.
References
-
- January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, Cleveland JC Jr, et al. 2014 AHA/ACC/HRS Guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2014;64:e1–e76. - DOI
-
- Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. 2012 HRS/EHRA/ECAS Expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace. 2012;14:528–606. - DOI
-
- Fuster V, Rydén LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, et al. 2011 ACCF/AHA/HRS focused updates incorporated into the ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: a report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines. Circulation. 2011;123:e269–367. - PubMed
-
- Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66. - DOI
-
- Liu X, Dong J, Mavrakis HE, Hu F, Long D, Fang D, et al. Achievement of pulmonary vein isolation in patients undergoing circumferential pulmonary vein ablation: a randomized comparison between two different isolation approaches. J Cardiovasc Electrophysiol. 2006;17:1263–70. - DOI