Thrombotic and bleeding complications of prosthetic heart valves
Abstract
A review of articles published since 1979 indicates that thrombotic and bleeding complications account for about 50% of valve-related complications in patients with bioprosthetic aortic and mitral valves and for approximately 75% of the complications in patients with mechanical valves. Although compromised by lack of standard definitions and by variability in reporting and follow-up, the data suggest that the linearized rate of both thrombotic and bleeding complications in patients with aortic bioprostheses is approximately half that for aortic mechanical prostheses (2% versus 4%), but is approximately equal for both bioprostheses and mechanical valves in the mitral position (approximately 4%), and for mechanical and bioprosthetic aortic and mitral valves in combination. However, linearized rates for fatal thrombotic and bleeding events are two to four times higher in patients with mechanical prostheses. The adequacy of warfarin anticoagulation is the most important factor affecting thrombotic and bleeding complications in patients with mechanical valves and over shadows the dubious importance of other phenomena such as atrial fibrillation and left atrial thrombus. Short-term warfarin anticoagulation or the use of long-term platelet inhibitors, or both, do not appear to reduce the incidence of thrombotic complications in patients with aortic bioprostheses but increase bleeding. For mitral bioprostheses, the postoperative use of warfarin for three months or aspirin indefinitely is as effective in preventing thromboembolism as long-term warfarin. Acute prosthetic valve endocarditis is associated with a 13 to 40% incidence of thrombotic complications. Likewise, the recurrence rate of cerebral emboli is high (20-30%) in patients with prosthetic valves who are not anticoagulated. Bioprostheses are strongly preferred for women who wish to bear children; fetal wastage occurs in 25 to 30% of pregnant women with mechanical heart valves who receive either warfarin or heparin, or a combination of the two. Heparin, however, greatly increases the risk of maternal bleeding. In children, the efficacy of platelet inhibitors without warfarin anticoagulation is unproven; nearly all serious strokes occur when warfarin is omitted; and permanent disability from warfarin-related bleeding is rare. All prosthetic cardiac valves initiate coagulation and affect the dynamic equilibrium between activated procoagulants and endogenous anticoagulants. Warfarin is the only available oral exogenous anticoagulant.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
Valvular Heart Disease in Adults: Management of Prosthetic Heart Valves.FP Essent. 2017 Jun;457:23-29. FP Essent. 2017. PMID: 28671806 Review.
-
Early anticoagulation of bioprosthetic aortic valves in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database.J Am Coll Cardiol. 2012 Sep 11;60(11):971-7. doi: 10.1016/j.jacc.2012.05.029. Epub 2012 Aug 22. J Am Coll Cardiol. 2012. PMID: 22921973
-
Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves.Chest. 2001 Jan;119(1 Suppl):220S-227S. doi: 10.1378/chest.119.1_suppl.220s. Chest. 2001. PMID: 11157651 Review.
-
Bioprosthetic and mechanical valves in the elderly: benefits and risks.Ann Thorac Surg. 1995 Aug;60(2 Suppl):S443-6. doi: 10.1016/0003-4975(95)00252-g. Ann Thorac Surg. 1995. PMID: 7646205
-
Late incidence and determinants of stroke after aortic and mitral valve replacement.Ann Thorac Surg. 2004 Jul;78(1):77-83; discussion 83-4. doi: 10.1016/j.athoracsur.2003.12.058. Ann Thorac Surg. 2004. PMID: 15223407
Cited by
-
[INR Self-management after mechanical heart valve replacement: ESCAT (Early Self-Controlled Anticoagulation Trial)].Z Kardiol. 2001 Dec;90(Suppl 6):118-24. doi: 10.1007/s003920170019. Z Kardiol. 2001. PMID: 24445799 German.
-
Thrombolytic therapy for prosthetic pulmonary valve thrombosis.Clin Res Cardiol. 2006 Aug;95(8):413-7. doi: 10.1007/s00392-006-0394-7. Epub 2006 Jun 13. Clin Res Cardiol. 2006. PMID: 16741629 No abstract available.
-
Which One to Treat When Pannus and Thrombus Coexist in a Mechanical Aortic Valve?: An Equivocal Case.JACC Case Rep. 2021 Apr 21;3(4):533-536. doi: 10.1016/j.jaccas.2021.02.021. eCollection 2021 Apr. JACC Case Rep. 2021. PMID: 34317576 Free PMC article.
-
Prosthetic tricuspid valve thrombosis: three case reports and literature review.J Tehran Heart Cent. 2012 Nov;7(4):147-55. Epub 2012 Nov 30. J Tehran Heart Cent. 2012. PMID: 23323074 Free PMC article.
-
Aortic valve replacement with autologous pericardium: long-term follow-up of 15 patients and in vivo histopathological changes of autologous pericardium.Interact Cardiovasc Thorac Surg. 2013 Feb;16(2):123-8. doi: 10.1093/icvts/ivs441. Epub 2012 Nov 8. Interact Cardiovasc Thorac Surg. 2013. PMID: 23143205 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical