Observational Study
. 2022 Jun;35(7):767-775.
doi: 10.1055/s-0040-1718599. Epub 2020 Oct 27.

The Journey Bicruciate Knee Replacement: Design Modifications Yield Better Early Functional Results and Reduce Complications

Affiliations
Observational Study

The Journey Bicruciate Knee Replacement: Design Modifications Yield Better Early Functional Results and Reduce Complications

Lazaros Oikonomidis et al. J Knee Surg. 2022 Jun.

Abstract

The Journey-I total knee replacement was designed to improve knee kinematics but had several complications including early dislocation. The Journey-II modification was introduced to reduce these while maintaining high function. To assess whether the modified Journey-II prosthesis has succeeded in its designers aims, we undertook an observational study of prospectively recorded data to analyze and compare the two knees. A total of 217 Journey-I and 129 Journey-II knees were identified from the department's prospectively collated registry and were assessed at 1 year by a comparative statistical analysis using numerous factors including pain, functional activity, physical assessment, Short Form-12 (SF-12), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and Oxford scores. The statistical tests included Chi-square, Wilcoxon's rank and Mann-Whitney U-tests with the level of significance set at p < 0.05. There was a variation in primary patella resurfacing between the two groups with 14.3% in the Journey-I cohort and 66.7% in the Journey-II cohort. Both replacements demonstrated excellent postoperative function, but the Journey II performed significantly better than Journey I with fewer complications (37 vs. 10) and better improvement in almost all clinical scores including pain (p < 0.01), mobility outcomes (p = 0.018), Oxford (p = 0.004), and WOMAC (p = 0.039) scores but not with flexion improvement and SF-12 score. There was significant improvement in patellofemoral pain postoperatively in both the Journey I (p = 0.011) and Journey II (p = 0.042) arthroplasty; however the primarily resurfaced patella in a Journey-II implant had better postoperative scores. The main complication of dislocation in the Journey I was not seen in the modified Journey-II implant with stiffness requiring intervention reduced in Journey II. These results suggest that the Journey II has improved short-term clinical outcomes compared with Journey I with reduction of dislocation and other complications.

PubMed Disclaimer

Conflict of interest statement