. 2021 Mar;15(3):320-328.
doi: 10.1111/crj.13301. Epub 2020 Dec 19.

Endobronchial ultrasound guided transbronchial cryobiopsy versus forceps biopsy in peripheral lung lesions

Affiliations

Endobronchial ultrasound guided transbronchial cryobiopsy versus forceps biopsy in peripheral lung lesions

Mohamed Torky et al. Clin Respir J. 2021 Mar.

Abstract

Introduction: Radial probe endobronchial ultrasound (RP-EBUS) is a modern technique for diagnosis of peripheral lung lesions. It is assumed that the addition of transbronchial cryobiopsy (TBCB) could increase the diagnostic value for RP-EBUS.

Objectives: The main objectives were to evaluate the efficacy and safety of RP-EBUS-guided TBCB for diagnosis of peripheral lung lesions and comparing it with RP-EBUS-guided transbronchial forceps biopsy.

Methods: Sixty patients with peripheral lung diseases were divided into two groups. Group I included 45 patients who were eligible for TBCB and they subjected to forceps transbronchial biopsy (forceps TBB) and TBCB guided by RP-EBUS. Fifteen patients who were not eligible for TBCB were included in group II and they were subjected to forceps TBB and/or cytology retrieval procedures guided by RP-EBUS.

Results: In group I, forceps TBB had sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of; 67.5%, 100%, 100%, 18.8%, and 69.8%, respectively, while TBCB had sensitivity, specificity, PPV, NPV, and accuracy of 75%, 100%, 100%, 23.1%, and 76.7%, respectively. The sensitivity in group II was 80% and the overall results including both groups were sensitivity, specificity, PPV, NPV, and accuracy of 85.2%, 100%, 100%, 42.8%, and 86.7%, respectively. Regarding the complications, only one patient (1.7%) had significant bleeding. One patient (1.7%) had pneumothorax and another patient (1.7%) suffered from hypoxemia.

Conclusions: RP-EBUS-guided TBCB is a safe and effective technique for diagnosis of peripheral lung lesions. TBCB has achieved higher diagnostic values and better quality of samples.

Keywords: bronchoscopy; interventional pulmonology; lung cancer; pathology.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Baaklini WA, Reinoso MA, Gorin AB, Sharafkaneh A, Manian P. Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. Chest. 2000;117:1049-1054.
    1. Rivera MP, Mehta AC,American College of Chest Physicians. Initial diagnosis of lung cancer: ACCP evidence-based clinical practice guidelines (2nd edition). Chest. 2007;132:131s-148s.
    1. Chen A, Chenna P, Loiselle A, Massoni J, Mayse M, Misselhorn D. Radial probe endobronchial ultrasound for peripheral pulmonary lesions. A 5-year institutional experience. Ann Am Thorac Soc. 2014;11:578-582.
    1. Steinfort DP, Vincent J, Heinze S, Antippa P, Irving LB. Comparative effectiveness of radial probe endobronchial ultrasound versus CT-guided needle biopsy for evaluation of peripheral pulmonary lesions: a randomized pragmatic trial. Respir Med. 2011;105:1704-1711.
    1. Poletti V, Casoni GL, Gurioli C, Ryu JH, Tomassetti S. Lung cryobiopsy: a paradigm shift in diagnostic bronchoscopy? Respirology. 2014;19:645-654.

LinkOut - more resources