Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2021 Jan;32(1):3-12.
doi: 10.1097/ICU.0000000000000723.

FOCUSED (Femtosecond Optimized Continuous Uncorrected Sight with EDOF and Diffractive Multifocal IOLs) - A Review

Affiliations
Review

FOCUSED (Femtosecond Optimized Continuous Uncorrected Sight with EDOF and Diffractive Multifocal IOLs) - A Review

Brad P Barnett. Curr Opin Ophthalmol. 2021 Jan.

Abstract

Purpose of review: The aim of this article is to review techniques to maximize all-distance uncorrected visual acuity and minimize photic phenomena after the implantation of multifocal and extended-depth of focus (EDOF) intraocular lenses (IOLs). This review examines the role of femtosecond laser-assisted cataract surgery (FLACS) in postoperative minimization of astigmatism and optimization of outcomes with multifocal and EDOF lenses.

Recent findings: By incorporating intraoperative and preoperative imaging, femtosecond platforms such as those that utilize iris or conjunctival vessel registration, can enable a precision of corneal incisions and toric IOL markings that enable the lowest possible postoperative levels of astigmatism. Current studies suggest that with increasing IOL complexity, that is, trifocal versus bifocal, image degradation with even low levels of postoperative astigmatism are increased. To this end, current data support the utility of femtosecond laser arcuate incisions to enable the achievement of 0.5 D or less postoperative astigmatism for best outcomes with multifocal lenses.

Summary: The synergistic combination of multifocal/EDOF IOLs with FLACS is an extremely promising route in achieving postoperative spectacle independence for patients. The marriage of the precision of FLACS with the increasing complexity of multifocal/EDOF IOLs will fuel nomogram adjustment and systematic improvements, such as the Wörtz-Gupta formula. Such strategies provide an unprecedented precision to cataract surgery that makes FOCUSED (Femtosecond Optimized Continuous Uncorrected Sight with EDOF and Diffractive Multifocal IOLs) a reality.

PubMed Disclaimer

References

    1. Ferrer-Blasco T, Montes-Mico R, Peixoto-de-Matos SC, et al. Prevalence of corneal astigmatism before cataract surgery. J Cataract Refract Surg 2009; 35:70–75.
    1. Byun YS, Kim S, Lazo MZ, et al. Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser-assisted cataract surgery: factors in outcomes. J Cataract Refract Surg 2018; 44:202–208.
    1. Kessel L, Andresen J, Tendal B, et al. Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 2016; 123:275–286.
    1. Ruckl T, Dexl AK, Bachernegg A, et al. Femtosecond laser-assisted intrastromal arcuate keratotomy to reduce corneal astigmatism. J Cataract Refract Surg 2013; 39:528–538.
    1. Hayashi K, Sato T, Igarashi C, Yoshida M. Effect of spherical equivalent error on visual acuity at various distances in eyes with a trifocal intraocular lens. J Refract Surg 2019; 35:274–279.

MeSH terms

LinkOut - more resources