. 1987 Jul-Aug;24(4):159-64.
doi: 10.3928/0191-3913-19870701-03.

Artifacts of measuring during strabismus surgery

Affiliations

Artifacts of measuring during strabismus surgery

B J Kushner et al. J Pediatr Ophthalmol Strabismus. 1987 Jul-Aug.

Abstract

Several different artifacts can induce errors in measurements obtained during strabismus surgery. Fixating the severed rectus muscle stump with forceps during strabismus surgery can result in a temporary anterior displacement of the insertion. This may result in inaccuracies in determining the site to which the muscle is to be recessed. This displacement was quantified in a prospective masked manner and was found in some patients to result in as much as 1 mm of error. It can be prevented by measuring the recession prior to fixating the insertion stump with forceps; however, it cannot always be prevented by measuring from the limbus, which also introduces other artifacts due to geometric principles. An "advancement effect" occurs during a rectus muscle recession due to the mechanics of suture placement in the muscle. It was quantified in a masked manner and found to be approximately .5 mm in most cases. A "V" shaped deformity of the insertion stump may occur immediately adjacent to the forceps. This deformity frequently distorts the insertion by as much as several millimeters.

PubMed Disclaimer