Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan;32(1):106-112.
doi: 10.1016/j.jvir.2020.09.023. Epub 2020 Oct 27.

Intravesical Prostatic Protrusion Does Not Influence the Efficacy of Prostatic Artery Embolization

Affiliations

Intravesical Prostatic Protrusion Does Not Influence the Efficacy of Prostatic Artery Embolization

Marcio Meira et al. J Vasc Interv Radiol. 2021 Jan.

Abstract

Purpose: To compare the outcomes of prostatic artery embolization (PAE) in patients with different intravesical prostatic protrusion (IPP) grades.

Materials and methods: This retrospective single-center study included 128 patients (aged 50-86 years) who underwent PAE from 2013 to 2017. IPP grades were classified as follows: grade I (<10 mm), grade II (10-19 mm), and grade III (≥20 mm). Nineteen patients (14.8%) had grade I [mean IPP 7.8 mm, prostatic volume (PV) 64.1 cm3], 77 (60.2%) had grade II (mean IPP 14.9 mm, PV 87.0 cm3), and 32 (25%) had grade III (mean IPP 26.2 mm, PV 132.6 cm3), P < .01. The outcomes, including PV, international prostate symptom score (IPSS), and quality of life (QoL), were compared between the IPP grades at the 12-month follow-up. Clinical failure was defined as IPSS >7 or QoL >2.

Results: IPP decreased (I: -8.2%, II: -27.3%, and III: -38.7%, P = .01), and all other endpoints improved (P < .01). Adjusted covariance analysis, considering baseline PV as a confounding factor, showed no correlation between the 12-month outcomes and baseline IPP. Clinical failure was observed in 17/128 patients (13.3%) and was similar in prevalence among the IPP groups (P = .20). Minor complications occurred in 43 patients (33.6%) and major in 3 (2.3%). There were statistical differences in the complications between IPP grades II and III (P < .01).

Conclusions: PAE was similarly effective in all the IPP grades at the 12-month follow-up, and there was no difference in the clinical failure between the groups. Complications in IPP grade III were more frequent than those in IPP grade II.

PubMed Disclaimer

MeSH terms

LinkOut - more resources