Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Sep;54(3):273-282.
doi: 10.15644/asc54/3/5.

Effect of Saliva Contamination on Microleakage of Open Sandwich Restorations

Affiliations

Effect of Saliva Contamination on Microleakage of Open Sandwich Restorations

Çiğdem Çelik et al. Acta Stomatol Croat. 2020 Sep.

Abstract

Objectives: The purpose of the present study was to evaluate the microleakage of conventional glass-ionomer, resin modified glass-ionomer and glass hybrid ionomer Class II open sandwich restorations with or without saliva contamination.

Materials and methods: Sixty extracted sound human molar teeth were used and 120 class II slot cavities were prepared in mesial and distal surfaces. The gingival margins were located 1 mm below the cementoenamel junction. All specimens were randomly divided in 4 groups (n=15): Group I: High-Viscous Glass Ionomer (Fuji IX GP) Group II: Resin Modified Glass Ionomer (Fuji II LC) Group III: Glass Hybrid Ionomer (Equia-fil Forte), Group IV: Composite Resin (G'aenial Posterior). In open sandwich restoration groups, glass ionomer materials were placed to gingival floor in 1 mm thickness and rest of the cavity was filled with resin composite. After the restorations in mesial surfaces had been performed, distal cavities were restored with the same protocol after saliva contamination. The specimens were thermo-cycled for 10000 cycles at 50C to 550C and immersed in methylene blue dye solution (% 0,5) for 24 hours. Then, they were sectioned vertically through the center of the restorations from mesial to distal surface with a water-cooled diamond saw with 1mm thickness. Subsequently, the dye penetration was evaluated with image analysis software. Data were statistically analyzed (p<0.05).

Results: There was a statistically significant difference between gingival microleakage scores in no contamination groups, between high-viscous glass ionomer, Fuji IX GP and other materials tested (p<0.05). In saliva contaminated groups, there was no statistically significant difference between gingival microleakage scores (p>0.05). Additionally, there was not a statistically significant difference between the no contamination and saliva contaminated groups regardless of dental materials tested (p>0.05).

Conclusion: Within the limitations of this study, in open sandwich restorations, saliva contamination did not show an adverse effect on microleakage irrespective of dental materials tested. Glass hybrid ionomers and resin modified glass ionomers showed lower microleakage scores in gingival margins compared to high-viscous glass ionomer material in no contamination groups.

Keywords: Composite Resins; Dental Leakage; Glass Ionomer Cements; Permanent Dental Restoration.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest The authors declare that they have no conflict of interest.

Figures

Figure 1
Figure 1
Microleakage scores of groups tested.

References

    1. Ehrnford L, Derand T. Cervical gap formation in class II composite resin restorations. Swed Dent J. 1984;8(1):15–9. - PubMed
    1. Aboushala A, Kugel G, Hurley E. Class II composite resin restorations using glass-ionomer liners: microleakage studies. J Clin Pediatr Dent. 1996. Fall;21(1):67–70. - PubMed
    1. Dietrich T, Lösche A, Lösche G, Roulet J-F. Marginal adaptation of direct composite and sandwich restorations in Class II cavities with cervical margins in dentin. J Dent. 1999. February;27(2):119–28. 10.1016/S0300-5712(98)00035-9 - DOI - PubMed
    1. McCabe JF. Resin-modified glass-ionomers. Biomaterials. 1998. March;19(6):521–7. 10.1016/S0142-9612(98)00132-X - DOI - PubMed
    1. Crim GA, Chapman KW. Reducing microleakage in Class II restorations: An in vitro study. Quintessence Int. 1994. November;25(11):781–5. - PubMed

LinkOut - more resources