Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2020 Nov 16;20(1):695.
doi: 10.1186/s12884-020-03362-4.

Safety and efficacy of manual vacuum suction compared with conventional dilatation and sharp curettage and electric vacuum aspiration in surgical treatment of miscarriage: a randomized controlled trial

Affiliations
Randomized Controlled Trial

Safety and efficacy of manual vacuum suction compared with conventional dilatation and sharp curettage and electric vacuum aspiration in surgical treatment of miscarriage: a randomized controlled trial

Toshiyuki Kakinuma et al. BMC Pregnancy Childbirth. .

Abstract

Background: The World Health Organization does not recommend dilatation and sharp curettage (D&C) for the surgical treatment of miscarriage during the first trimester because this may cause Asherman's syndrome due to endometrial damage; therefore, suction remains the primary treatment option. While manual vacuum aspiration (MVA) has been widely used since the 1990s outside Japan, the use of an MVA device (Women's MVA system) was approved in Japan in October 2015. Here, we examined the efficacy of the MVA kit in women surgically treated for miscarriage.

Methods: This retrospective cohort study was conducted between 2014 and 2018 at the International University of Health and Welfare Hospital in Japan. Women who underwent surgical treatment for miscarriage within 12 weeks of pregnancy were identified and enrolled in the study. A total of 404 women were included who underwent the following procedures: 121 D&C, 123 electric vacuum aspiration (EVA), and 160 MVA. For each participant, the duration of surgery, amount of bleeding, amount of anesthetic used, incomplete abortion requiring repeat procedures, and intraoperative/postoperative complications were evaluated.

Results: The duration of surgery was 13.7 ± 7.2, 11.2 ± 4.2, and 6.9 ± 4.3 min in the D&C, EVA, and MVA groups, respectively (p = 1.00). The amount of anesthetic used was not significantly different among all groups. Bleeding of ≥ 100 mL was confirmed in three (2.4%), one (0.8%), and one (0.6%) patient(s) in the D&C, EVA, and MVA groups, respectively (p = 0.50). Incomplete abortion was identified in three (2.4%), two (1.6%), and one (0.6%) patient(s) in the D&C, EVA, and MVA groups, respectively (p = 0.61). However, severe intraoperative/postoperative complications were not observed in any group.

Conclusions: Surgical treatment for miscarriage performed using the MVA kit has safety and efficacy similar to those of conventional methods, such as D&C and EVA.

Keywords: Asherman’s syndrome; Dilation and curettage; Electric vacuum aspiration; Manual vacuum aspiration.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no competing interests.

Figures

Fig. 1
Fig. 1
Comparison of endometrial thickness before and after MVA (represented in mean +/- SD). Endometrial thickness before and after miscarriage surgery from ovulation to implantation was compared in the MVA group and showed no thinning of the endometrium

Similar articles

Cited by

References

    1. Sekiguchi A, Ikeda T, Okamura K, Nakai A. Safety of induced abortions at less than 12 weeks of pregnancy in Japan. Int J Gynaecol Obstet. 2015;129:54–7. - PubMed
    1. Harvey K, Potts M. Very early abortion using syringe as vacuum source. Lancet. 1972;299:1051–2. - PubMed
    1. Wen J, Cai QY, Deng F, Li YP. Manual versus electric vacuum aspiration for first-trimester abortion: a systematic review. BJOG. 2008;115:5–13. - PubMed
    1. Goldberg AB, Dean G, Kang MS, Youssof S, Darney PD. Manual versus electric vacuum aspiration for early first-trimester abortion: a controlled study of complication rates. Obstet Gynecol. 2004;103:101–7. - PubMed
    1. Verkuyl DA, Crowther CA. Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. S Afr Med J. 1993;83:13–5. - PubMed

Publication types