. 2020 Nov 7;6(4):210-216.
doi: 10.2478/jccm-2020-0030. eCollection 2020 Oct.

Feasibility and Safety of Peripheral Intravenous Administration of Vasopressor Agents in Resource-limited Settings

Affiliations

Feasibility and Safety of Peripheral Intravenous Administration of Vasopressor Agents in Resource-limited Settings

Ajay Padmanaban et al. J Crit Care Med (Targu Mures). .

Abstract

Background: Vasopressors are conventionally administered through a central venous catheter (CVC) and not through a peripheral venous catheter (PVC) since the latter is believed to be associated with increased risk of extravasation. Placement of a CVC requires suitably trained personnel to be on hand, and in resource-limited settings, this requirement may delay placement. Because of this and in cases where suitably trained personnel are not immediately available, some clinicians may be prompted to utilise a PVC for infusing vasopressors. The objective of this study is to assess the feasibility and safety of vasopressors administered through a PVC.

Materials and methods: Patients who received vasopressors through a PVC for more than one hour were included in a single centre, consecutive patient observational study. Patients with a CVC at the time of initiation of vasopressors were excluded. Data regarding the size, location of PVCs, dose, duration and number of vasopressors infused were recorded. The decision to place CVC was left to the discretion of the treating physician. Extravasation incidents, severity and management of such events were recorded.

Results: One hundred twenty-two patients age 55(4) years [mean (SD)] were included in the study. The commonest PVC was of 18G calibre (57%), and the most common site of placement was the external jugular vein (36.5%). Noradrenaline was the most common vasopressor used at a dose of 10.6 (7) mcg/min [mean (SD)] and the median duration of nine hours (IQR: 6-14). CVC was placed most commonly due to an increasing dose of vasopressors after 4.5(4) hours [mean (SD)]. Grade 2 Extravasation injury occurred in one patient after prolonged infusion of fifty-two hours, through a small calibre (20G) PVC, which was managed conservatively without any sequelae.

Conclusion: Vasopressors infused through a PVC of 18G or larger calibre into the external jugular, or a forearm vein is feasible and safe. Clinicians need to balance the safety of peripheral vasopressor infusion with the additional costs and complications associated with CVC in resource-limited settings.

Keywords: central venous catheter; hemodynamic emergencies; peripheral venous catheter; vasopressors.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest None to declare.

Figures

Fig. 1
Fig. 1
PVC Size & Site Used

References

    1. Kahn JM, Kress JP, Hall JB. Skin necrosis after extravasation of low-dose vasopressin administered for septic shock. Crit Care Med. 2002;30(8):1899–901. - PubMed
    1. Bunker N, Higgins D. Peripheral administration of vasopressin for catecholamine-resistant hypotension complicated by skin necrosis. Crit Care Med. 2006;34(3):935. - PubMed
    1. McGee DC, Gould MK.. Preventing complications of central venous catheterisation. N Engl J Med. 2003;348(12):1123–33. - PubMed
    1. Polderman KH, Girbes ARJ. Central venous catheter use: Part 2: Infectious complications. Intensive Care Med. 2002;28(1):18–28. - PubMed
    1. Beck V, Chateau D, Bryson GL. Timing of vasopressor initiation and mortality in septic shock: A cohort study. Crit Care. 2014;18(3):R97. et al. - PMC - PubMed

LinkOut - more resources