Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Nov;75(6):635-641.

Ultrasound findings of plasma leakage as imaging adjunct in clinical management of dengue fever without warning signs

Affiliations
  • PMID: 33219170
Free article

Ultrasound findings of plasma leakage as imaging adjunct in clinical management of dengue fever without warning signs

C Xin Tian et al. Med J Malaysia. 2020 Nov.
Free article

Abstract

Introduction: Plasma leakage is a major cause of morbidity and mortality in dengue fever. Few studies have shown the sensitivity of thoracoabdominal ultrasound in detecting plasma leakage in severe dengue, however its sensitivity in the early presentation of dengue fever without warning signs remains unknown. This study is aimed to determine the role of serial ultrasound in order to detect plasma leakage in dengue fever without warning signs.

Methods: This prospective cohort study was conducted at Hospital Universiti Sains Malaysia (USM) from 1st October 2016 to 30th November 2017. Serial bedside ultrasound procedures were performed for 83 patients who were diagnosed as having dengue fever without warning signs and were initially treated as outpatients. Ultrasonography evidence of plasma leakage either pleural effusion, thickened gallbladder wall, ascites or pericardial effusion were compared with clinical findings and laboratory parameters for plasma leakage.

Results: Of the 83 dengue patients, eventually 72.3% had dengue fever with warning signs and 6.0% had severe dengue fever. There were 38 patients who had subclinical plasma leakage at initial presentation, 84.2% and 7.9% of them then progressed to dengue fever with warning signs and severe dengue respectively. There was a minimal agreement between serial bedside ultrasound and haematocrit level in the detection of plasma leakage (observed kappa 0.135).

Conclusions: Serial bedside ultrasound is an adjunct procedure to physical examination and may detect plasma leakage earlier compared to haemoconcentration. The early usage of serial ultrasound is of paramount importance in detecting dengue patients who are at risk of progressing to severe dengue.

PubMed Disclaimer

LinkOut - more resources