Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model
- PMID: 33227321
- DOI: 10.1016/j.arthro.2020.10.031
Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model
Abstract
Purpose: To compare tibiofemoral contact mechanics after horizontal or ripstop (horizontal plus vertical) sutures in inside-out and transtibial repair for meniscal radial tears with 10 porcine knees in each group.
Methods: Ten matched pairs of porcine knees were tested under a 1500-N axial compressive load at 0°, 30°, 60°, and 90° of knee flexion. Each knee underwent 4 testing conditions consecutively: (1) intact, (2) medial meniscal radial tear, (3) horizontal suture repair configuration, and (4) ripstop suture repair configuration. Tekscan sensors measured tibiofemoral contact pressure and contact area in the medial and lateral compartments.
Results: All repair groups improved their contact mechanics when compared with the tear state among all flexion angles analyzed (all P < .05). Furthermore, ripstop sutures with both inside-out and transtibial repairs restored intact knee contact area and pressures (peak and mean) in the medial compartment at all flexion angles, whereas the horizontal sutures alone failed to do so for contact pressures at 60° and 90° and for contact surface areas at all flexion angles. However, the aforementioned parameters were not significantly different between inside-out sutures and transtibial sutures, regardless of horizontal or ripstop configuration (P > .05).
Conclusions: Radial tears of the meniscus in a porcine model significantly decreased medial contact area and increased mean and peak contact pressure. Both inside-out and transtibial ripstop repairs for radial tears aid in restoring intact tibiofemoral contact mechanics at all assessed knee flexion angles.
Clinical relevance: Our results suggest that both inside-out and transtibial ripstop repairs for radial tears can restore tibiofemoral contact mechanics to the intact state. Since the study were performed in an open fashion porcine model, the results should be carefully used in clinical practices, and the efficacy of the techniques through arthroscopic method should be further explored.
Copyright © 2020 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comment in
-
Editorial Commentary: Efforts to Heal Meniscal Radial Tears Are Ongoing.Arthroscopy. 2021 Mar;37(3):941-943. doi: 10.1016/j.arthro.2020.12.002. Arthroscopy. 2021. PMID: 33673972
Similar articles
-
Utilization of Transtibial Centralization Suture Best Minimizes Extrusion and Restores Tibiofemoral Contact Mechanics for Anatomic Medial Meniscal Root Repairs in a Cadaveric Model.Am J Sports Med. 2019 Jun;47(7):1591-1600. doi: 10.1177/0363546519844250. Epub 2019 May 15. Am J Sports Med. 2019. PMID: 31091129
-
Biomechanical Comparison of Vertical Mattress and Cross-stitch Suture Techniques and Single- and Double-Row Configurations for the Treatment of Bucket-Handle Medial Meniscal Tears.Am J Sports Med. 2019 Apr;47(5):1194-1202. doi: 10.1177/0363546519830402. Epub 2019 Mar 21. Am J Sports Med. 2019. PMID: 30897004
-
A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.Am J Sports Med. 2016 Mar;44(3):639-45. doi: 10.1177/0363546515615565. Epub 2015 Dec 8. Am J Sports Med. 2016. PMID: 26646516
-
Several Techniques Exist With Favorable Biomechanical Outcomes in Radial Meniscus Tear Repair-A Systematic Review.Arthroscopy. 2022 Aug;38(8):2557-2578.e4. doi: 10.1016/j.arthro.2022.02.010. Epub 2022 Feb 19. Arthroscopy. 2022. PMID: 35189305
-
Neither All-Inside, nor Inside-Out, nor Outside-In Repair Demonstrates Superior Biomechanical Properties for Vertical Meniscal Tears: A Systematic Review of Human Cadaveric Studies.Arthroscopy. 2025 Apr;41(4):1163-1180.e2. doi: 10.1016/j.arthro.2024.03.049. Epub 2024 Jun 14. Arthroscopy. 2025. PMID: 38880182
Cited by
-
Animal models used in meniscal repair research from ex vivo to in vivo: A systematic review.J Orthop. 2024 Apr 4;55:23-31. doi: 10.1016/j.jor.2024.03.038. eCollection 2024 Sep. J Orthop. 2024. PMID: 38638113 Review.
-
Modified Mason-Allen with Mattress Sutures and Double Row Suture Bridge in Musculotendinosis Rotator Cuff Tear.Arthrosc Tech. 2025 Apr 3;14(6):103541. doi: 10.1016/j.eats.2025.103541. eCollection 2025 Jun. Arthrosc Tech. 2025. PMID: 40656715 Free PMC article.
-
Repair Technique for Displaced Meniscal Flap Tears Indicated by MRI Comma Sign.Arthrosc Tech. 2021 Dec 27;11(1):e79-e87. doi: 10.1016/j.eats.2021.09.004. eCollection 2022 Jan. Arthrosc Tech. 2021. PMID: 35127432 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources