Advances in the fracture mechanics of cortical bone
- PMID: 3323199
- DOI: 10.1016/0021-9290(87)90025-x
Advances in the fracture mechanics of cortical bone
Abstract
As cortical bone is a semi-brittle solid, its fracture is dependent not only on the magnitude of the applied stress, but also on the nature of any intrinsic or introduced cracks. Consequently a variety of fracture mechanics techniques have been utilised to evaluate the fracture toughness of cortical bone, including the single edge notched, centre notched cylindrical and compact tension methods, and values have been established for the critical stress intensity factor (Kc) and the critical strain energy release rate (Gc). The Kc and Gc values obtained depend on the orientation of the cortical bone, as well as on bone density, the velocity of crack propagation and specimen geometry. The significance of these fracture mechanics parameters for cortical bone is critically reviewed.
Similar articles
-
Fracture toughness of human bone under tension.J Biomech. 1995 Mar;28(3):309-20. doi: 10.1016/0021-9290(94)00069-g. J Biomech. 1995. PMID: 7730389
-
Fracture mechanics of bone--the effects of density, specimen thickness and crack velocity on longitudinal fracture.J Biomech. 1984;17(1):25-34. doi: 10.1016/0021-9290(84)90076-9. J Biomech. 1984. PMID: 6715385
-
Effect of groove on bone fracture toughness.J Biomech. 1992 Dec;25(12):1489-92. doi: 10.1016/0021-9290(92)90061-5. J Biomech. 1992. PMID: 1491024
-
Fracture mechanics of bone.J Biomech Eng. 1993 Nov;115(4B):549-54. doi: 10.1115/1.2895538. J Biomech Eng. 1993. PMID: 8302039 Review.
-
Fracture length scales in human cortical bone: the necessity of nonlinear fracture models.Biomaterials. 2006 Mar;27(9):2095-113. doi: 10.1016/j.biomaterials.2005.09.040. Epub 2005 Nov 4. Biomaterials. 2006. PMID: 16271757 Review.
Cited by
-
Design and performance analysis of low damage anti-skid crescent drills for bone drilling.J Orthop Surg Res. 2024 Aug 17;19(1):489. doi: 10.1186/s13018-024-04983-7. J Orthop Surg Res. 2024. PMID: 39153973 Free PMC article.
-
Theoretical relationship between maximum pore size and toughness in experimental inflammatory arthritis.J Mater Sci Mater Med. 2000 May;11(5):313-8. doi: 10.1023/a:1008913501297. J Mater Sci Mater Med. 2000. PMID: 15348029
-
Coupling of HDPE/hydroxyapatite composites by silane-based methodologies.J Mater Sci Mater Med. 2003 Jun;14(6):475-87. doi: 10.1023/a:1023471011749. J Mater Sci Mater Med. 2003. PMID: 15348431
-
Small animal bone biomechanics.Bone. 2008 Nov;43(5):794-7. doi: 10.1016/j.bone.2008.06.013. Epub 2008 Jul 4. Bone. 2008. PMID: 18672104 Free PMC article.
-
Osteoprotective effect of Achyranthes bidentata root extract on osteoporotic rats: a systematic review and meta-analysis.Pharm Biol. 2024 Dec;62(1):691-701. doi: 10.1080/13880209.2024.2407531. Epub 2024 Oct 3. Pharm Biol. 2024. PMID: 39363520 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous