Application of triple quadrupole tandem mass spectrometry to the bioanalysis of collision-induced dissociation-resistant cyclic peptides - Ultra-sensitive quantification of the somatostatin-analog pasireotide utilizing UHPLC-MS/MS
- PMID: 33234413
- DOI: 10.1016/j.jpba.2020.113728
Application of triple quadrupole tandem mass spectrometry to the bioanalysis of collision-induced dissociation-resistant cyclic peptides - Ultra-sensitive quantification of the somatostatin-analog pasireotide utilizing UHPLC-MS/MS
Abstract
Cyclic peptides are considered collision-induced dissociation (CID)-resistant due to immobile protons, and the necessity of at least two consecutive dissociation reactions to produce fragments with deviating m/z values. Therefore, the bioanalysis of cyclic peptides by tandem mass spectrometry (MS/MS) poses a major challenge, especially on triple quadrupole (TQ) instruments. One of these peptides is the somatostatin analog pasireotide, a cyclic hexapeptide administered to treat Cushing's disease and acromegaly. To support oral formulation development, sub-therapeutic quantification of pasireotide is highly beneficial. Regardless of the considered CID-resistance, we investigated the CID-characteristics of pasireotide and subsequently developed an ultra-sensitive UHPLC-MS/MS assay with a lower limit of quantification (LLOQ) of 5 pg/mL (4.9 pM) when using 100 μL of plasma and validated it according to the guidelines of the FDA and EMA. The achieved sensitivity, which is the highest thus far reported, demonstrates that TQ-MS/MS is a feasible approach to sensitive quantification of cyclic peptides despite their CID-resistance. Pasireotide was fast and efficiently extracted by protein depletion via precipitation using acetonitrile. Correlation coefficients > 0.99 were achieved for all calibration curves with linear regression. Inter-run and intra-run accuracy ranged from 89.4 to 99.3 % with corresponding precision of ≤ 7.5 % in the calibrated range, and from 94.6 to 105.6 % with corresponding precision of ≤ 14.5 % at the LLOQ. Quantification of 10-fold diluted samples showed an accuracy of 90.8 % and corresponding precision of 4.0 %. The assay was applied to the quantification of pasireotide plasma concentrations after intravenous administration to beagle dogs.
Keywords: Collision-induced dissociation-resistant; Cyclic peptide; Pasireotide; Plasma; Tandem mass spectrometry; UHPLC.
Copyright © 2020 Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest The authors declare no conflict of interest.
Similar articles
-
Post-extraction disulfide bond cleavage for MS/MS quantification of collision-induced dissociation-resistant cystine-cyclized peptides and its application to the ultra-sensitive UPLC-MS/MS bioanalysis of octreotide in plasma.Anal Chim Acta. 2020 Jun 1;1114:42-49. doi: 10.1016/j.aca.2020.04.016. Epub 2020 Apr 10. Anal Chim Acta. 2020. PMID: 32359513
-
Sensitive quantification of the somatostatin analog AP102 in plasma by ultra-high pressure liquid chromatography-tandem mass spectrometry and application to a pharmacokinetic study in rats.Drug Test Anal. 2018 Sep;10(9):1448-1457. doi: 10.1002/dta.2400. Epub 2018 May 29. Drug Test Anal. 2018. PMID: 29745052
-
Ultra-sensitive quantification of the therapeutic cyclic peptide bremelanotide utilizing UHPLC-MS/MS for evaluation of its oral plasma pharmacokinetics.J Pharm Biomed Anal. 2020 Jul 15;186:113276. doi: 10.1016/j.jpba.2020.113276. Epub 2020 Mar 27. J Pharm Biomed Anal. 2020. PMID: 32353679
-
An ultra-sensitive UHPLC-MS/MS assay for the quantification of orally administered vancomycin in plasma.J Pharm Biomed Anal. 2019 Sep 10;174:633-638. doi: 10.1016/j.jpba.2019.06.015. Epub 2019 Jun 27. J Pharm Biomed Anal. 2019. PMID: 31279892
-
Bioanalysis of lanreotide in dog plasma using liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study of beagle dogs after single subcutaneous injection.J Chromatogr B Analyt Technol Biomed Life Sci. 2022 Jan 1;1188:123078. doi: 10.1016/j.jchromb.2021.123078. Epub 2021 Dec 4. J Chromatogr B Analyt Technol Biomed Life Sci. 2022. PMID: 34891048
Cited by
-
Intact plasma quantification of the large therapeutic lipopeptide bulevirtide.Anal Bioanal Chem. 2021 Sep;413(22):5645-5654. doi: 10.1007/s00216-021-03384-7. Epub 2021 May 20. Anal Bioanal Chem. 2021. PMID: 34018034 Free PMC article.
-
Evaluation of PepT1 (SLC15A1) Substrate Characteristics of Therapeutic Cyclic Peptides.Pharmaceutics. 2022 Aug 1;14(8):1610. doi: 10.3390/pharmaceutics14081610. Pharmaceutics. 2022. PMID: 36015235 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials