Meta-Analysis
. 2021 Oct;53(10):1037-1047.
doi: 10.1055/a-1324-7919. Epub 2021 Mar 2.

Efficacy of lumen-apposing metal stents or self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Efficacy of lumen-apposing metal stents or self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy: a systematic review and meta-analysis

Arnaldo Amato et al. Endoscopy. 2021 Oct.

Abstract

Background: Endoscopic ultrasound (EUS)-guided biliary drainage is becoming an option for palliation of malignant biliary obstruction. Lumen-apposing metal stents (LAMS) are replacing self-expandable metal stents (SEMS). The aim of this meta-analysis was to evaluate the efficacy and safety of LAMS and SEMS for EUS-guided choledochoduodenostomy (EUS-CDS).

Methods: A meta-analysis was performed using PRISMA protocols. Electronic databases were searched for studies on EUS-CDS. The primary outcome was clinical success. Secondary outcomes were technical success, reintervention, and adverse events. We used the random effects model with the DerSimonian-Laird estimation, and the results were depicted using forest plots. Subgroup analyses were also performed with data stratified by selected variable.

Results: Overall, 31 studies (820 patients) were included. The pooled rates of clinical and technical success were 93.6 % (95 % confidence interval [CI] 88.6 %-96.5 %) and 94.8 % (95 %CI 90.2 %-97.3 %) for LAMS, and 91.7 % (95 %CI 88.1 %-94.2 %) and 92.7 % (95 %CI 89.9 %-94.9 %) for SEMS, respectively. The pooled rates of adverse events were 17.1 % (95 %CI 12.5 %-22.8 %) for LAMS and 18.3 % (95 %CI 14.3 %-23.0 %) for SEMS. The pooled rates of reintervention were 10.9 % (95 %CI 7.7 %-15.3 %) for LAMS and 13.9 % (95 %CI 9.6 %-19.7 %) for SEMS. Subgroup analyses confirmed these results.

Conclusions: This meta-analysis showed that LAMS and SEMS are comparable in terms of efficacy for EUS-CDS. Clinical and technical success, post-procedure adverse events, and reintervention rates were similar between LAMS and SEMS use; however, adverse events require further investigation.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no conflict of interest.

Comment in