Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Apr;36(4):1437-1444.
doi: 10.1016/j.arth.2020.10.054. Epub 2020 Nov 4.

Oxidized Zirconium Components Maintain a Smooth Articular Surface Except Following Hip Dislocation

Affiliations

Oxidized Zirconium Components Maintain a Smooth Articular Surface Except Following Hip Dislocation

Noah B Bonnheim et al. J Arthroplasty. 2021 Apr.

Abstract

Background: Oxidized zirconium (OxZr) offers theoretical advantages in total hip and knee arthroplasty (THA and TKA, respectively) relative to other biomaterials by combining the tribological benefits of ceramics with the fracture toughness of metals. Yet, some studies have found that OxZr does not improve outcomes or wear rates relative to traditional bearing materials such as cobalt-chromium (CoCr). Separately, effacement of the thin ceramic surface layer has been reported for OxZr components, though the prevalence and sequelae are unclear.

Methods: To elucidate the in vivo behavior of OxZr implants, the articular surfaces of 94 retrieved THA and TKA femoral components (43 OxZr TKA, 21 OxZr THA, 30 CoCr THA) were analyzed using optical microscopy, non-contact profilometry, and scanning electron microscopy.

Results: We found that OxZr components maintain a smooth articular surface except following hip dislocation. Three of four OxZr femoral heads revised following dislocation exhibited severe damage to the articular surface, including macroscopic regions of ceramic-layer effacement and exposure of the underlying metal substrate; these components were 23-32 times rougher than pristine OxZr controls. When revised for dislocation, OxZr femoral heads were substantially rougher than CoCr femoral heads (median Sa = 0.431 v. 0.020 μm, P = .03). In contrast, CoCr femoral heads exhibited low overall roughness values regardless of whether they dislocated (median Sa = 0.020 v. 0.008 μm, P = .09, CoCr dislocators v. non-dislocators).

Conclusions: Effacement of the ceramic surface layer and substantial articular surface roughening is not atypical following dislocation of OxZr femoral heads, making OxZr much less tolerant than CoCr to hip dislocation.

Keywords: dislocation; oxidized zirconium; oxinium; total hip arthroplasty; total knee arthroplasty.

PubMed Disclaimer

LinkOut - more resources