Comparison of a perfusion simulator to a clinical operating room: evaluation of eye tracking data and subjective perception. A pilot study
- PMID: 33249993
- DOI: 10.1177/0267659120974617
Comparison of a perfusion simulator to a clinical operating room: evaluation of eye tracking data and subjective perception. A pilot study
Abstract
Background: With the aim of evaluating the perfusion simulator at the German Heart Center Berlin, similarity between simulation and clinical operation room (OR) was investigated regarding subjective perception and eye movement.
Methods: Eight perfusionists performed an operation on the heart-lung machine (HLM) wearing eye tracking glasses, each in real OR and simulator. The three most important phases for perfusionists (going on bypass, cardioplegia administration and coming off bypass) were considered. Additional to eye tracking data as objective measure, questionnaires were completed, and interviews conducted afterwards.
Results: The structure of simulator and real OR is perceived as basically the same. Yet there are differences in the HLM-models used and the temporal sequence. Different perception of both situations is reported in interviews and reflected in significant differences in the rating scales (NASA-TLX) on three of six subscales. In eye tracking data, certain AOIs could be identified for the individual phases, both in OR and simulator-an indication of fundamental similarity. However, differences regarding the proportions of the individual AOIs, especially in the first and third phase, are leading to the assumption that the simulator, and especially the simulation process, is only valid to a limited extent regarding subjective perception and eye tracking data.
Conclusion: The use of the simulator for (advanced) training is accepted and explicitly requested by perfusionists. Yet further research is needed to identify the decisive factors (like simulation duration or additional tasks) for a valid execution in the simulator. Furthermore, a larger sample size should be regarded to allow statistical analysis.
Keywords: German Heart Center Berlin (DHZB); eye tracking; perception; perfusion simulator; simulator validation.
Similar articles
-
Evaluation of attention, perception, and stress levels of clinical cardiovascular perfusionists during cardiac operations: a pilot study.Perfusion. 2019 Oct;34(7):544-551. doi: 10.1177/0267659119828563. Epub 2019 Mar 14. Perfusion. 2019. PMID: 30868941
-
Simulation in perfusion: evaluating the efficacy of a specific training with eye-tracking.Perfusion. 2020 Nov;35(8):717-723. doi: 10.1177/0267659120918779. Epub 2020 May 18. Perfusion. 2020. PMID: 32420814
-
Eye-tracking analysis of skilled performance in clinical extracorporeal circulation.J Artif Organs. 2012 Jun;15(2):146-57. doi: 10.1007/s10047-012-0630-z. Epub 2012 Feb 17. J Artif Organs. 2012. PMID: 22350712
-
Eye-tracking during simulation-based echocardiography: a feasibility study.BMC Med Educ. 2023 Jul 1;23(1):490. doi: 10.1186/s12909-023-04458-z. BMC Med Educ. 2023. PMID: 37393288 Free PMC article.
-
Utility of Modern Arthroscopic Simulator Training Models: A Meta-analysis and Updated Systematic Review.Arthroscopy. 2018 May;34(5):1650-1677. doi: 10.1016/j.arthro.2017.10.048. Epub 2018 Jan 20. Arthroscopy. 2018. PMID: 29366742
Cited by
-
Eye tracking metrics of orthopedic surgeons with different competency levels who practice simulation-based hip arthroscopic procedures.Heliyon. 2022 Dec 14;8(12):e12335. doi: 10.1016/j.heliyon.2022.e12335. eCollection 2022 Dec. Heliyon. 2022. PMID: 36582732 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources