Corneal endothelial damage in phacoemulsification using an anterior chamber maintainer compared with using an ophthalmic viscosurgical device
- PMID: 33252564
- DOI: 10.1097/j.jcrs.0000000000000493
Corneal endothelial damage in phacoemulsification using an anterior chamber maintainer compared with using an ophthalmic viscosurgical device
Abstract
Purpose: To compare the effects of phacoemulsification surgery (PE) using an anterior chamber maintainer (ACM) and conventional PE using an ophthalmic viscosurgical device (OVD) on corneal endothelial cells.
Setting: Department of Ophthalmology, Celal Bayar University, Manisa, Turkey.
Design: Prospective randomized controlled trial.
Methods: Eyes in the OVD group (n = 50) underwent conventional PE, whereas eyes in the ACM group (n = 50) underwent PE using an ACM. Endothelial cell density (ECD), coefficient of variation (CV), hexagonality (HEX), and noncontact central corneal thickness (CCT) measurements were performed by specular microscopy before and at 1 month, 3 months, and 6 months after PE.
Results: This study included 100 eyes of 97 patients undergoing PE. The mean age was 64.7 ± 10.6 years in the OVD group, 64.0 ± 12.6 years in the ACM group (P > .05). The groups did not differ significantly in preoperative ECD, CV, HEX, and CCT or total PE time (P > .05 for all). ECD was significantly lower in the ACM group compared with the OVD group at postoperative 1 month, 3 months, and 6 months (P = .002, P = .002, and P = .001, respectively). Similarly, ECD loss compared with preoperative value was greater in the ACM group at all postoperative timepoints (P = .003, P = .001, and P = .001, respectively). CV increased and HEX decreased in both groups postoperatively (P > .05 for both). CCT showed a transient increase of less than 10 μm at postoperative 1 month in both groups (P = .296).
Conclusions: PE with ACM was associated with greater corneal ECD loss compared with conventional PE. ACM should not be used during PE in patients with limited corneal endothelial reserve.
Copyright © 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
References
-
- Wilhelm F, Holtkamp A, Duncker GI, Darman J Jr, Knorrn M. Phacoemulsification of human lens nucleus with a water jet. Ophthalmologe 2002;99:286–288
-
- Sugar J, Mitchelson J, Kraff M. The effect of phacoemulsification on corneal endothelial cell density. Arch Ophthalmol 1978;96:446–448
-
- Joussen MA, Barth U, Cubuk H, Hans-Reinhard K. Effect of irrigating solution and irrigating temperature on the cornea and pupil during phacoemulsification. J Cataract Refract Surg 2000;26:392–397
-
- Glasser DB, Matsuda M, Ellis JG, Edelhauser HF. Effects of intraocular irrigating solutions on the corneal endothelium after in vivo anterior chamber irrigation. Am J Ophthalmol 1985;99:321–328
-
- Tognett D, Cecchini P, Ravalico G. Survey of ophthalmic viscosurgical devices. Curr Opin Ophthalmol 2004;15:29–32
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources