Use of GoPro point-of-view camera in intubation simulation-A randomized controlled trial
- PMID: 33259536
- PMCID: PMC7707475
- DOI: 10.1371/journal.pone.0243217
Use of GoPro point-of-view camera in intubation simulation-A randomized controlled trial
Abstract
Introduction: Teaching endotracheal intubation is uniquely challenging due to its technical, high-stakes, and highly time-sensitive nature. The GoPro is a small, lightweight, high-resolution action camera with a wide-angle field of view that can encompass both the airway as well as the procedurist's hands and positioning technique when worn with a head mount. We aimed to evaluate its effectiveness in improving intubation teaching for novice learners in a simulated setting, via a two-arm, parallel group, randomized controlled superiority trial with 1:1 allocation ratio.
Methods: We recruited Year 4 medical students at the start of their compulsory 2-week Anesthesia posting. Participants underwent a standardized intubation curriculum and a formative assessment, then randomized to receive GoPro or non-GoPro led feedback. After a span of three months, participants were re-assessed in a summative assessment by blinded accessors. Participants were also surveyed on their learning experience for a qualitative thematic perspective. The primary outcomes were successful intubation and successful first-pass intubation.
Results: Seventy-one participants were recruited with no dropouts, and all were included in the analysis. 36 participants received GoPro led feedback, and 35 participants received non-GoPro led feedback. All participants successfully intubated the manikin. No statistically significant differences were found between the GoPro group and the non-GoPro group at summative assessment (85.3% vs 90.0%, p = 0.572). Almost all participants surveyed found the GoPro effective for their learning (98.5%). Common themes in the qualitative analysis were: the ability for an improved assessment, greater identification of small details that would otherwise be missed, and usefulness of the unique point-of-view footage in improving understanding.
Conclusions: The GoPro is a promising tool for simulation-based intubation teaching. There are considerations in its implementation to maximize the learning experience and yield from GoPro led feedback and training.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
References
-
- Cook TM, El-Boghdadly K, McGuire B, McNarry AF, Patel A, Higgs A. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetist. Anaesthesia. 2020;75: 785–799. 10.1111/anae.15054 - DOI - PMC - PubMed
-
- Son M, Zimmer D, McCauley R, Zimmer D, Dynako J, Skupski R, et al. Evaluation of Google Glass; with Camera Adaptor and GoPro; as Teaching Tools for Endotracheal Intubation in the Austere Medical Environment. Open J Anesthesiol. 2018;08: 229–239. 10.4236/ojanes.2018.88024 - DOI
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources