Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan:134:109424.
doi: 10.1016/j.ejrad.2020.109424. Epub 2020 Nov 21.

Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up

Affiliations

Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up

J Rueckel et al. Eur J Radiol. 2021 Jan.

Abstract

Objective: Follow-up of aortic aneurysms by computed tomography (CT) is crucial to balance the risks of treatment and rupture. Artificial intelligence (AI)-assisted radiology reporting promises time savings and reduced inter-reader variabilities.

Methods: The influence of AI assistance on the efficiency and accuracy of aortic aneurysm reporting according to the AHA / ESC guidelines was quantified based on 324 AI measurements and 1944 radiological measurements: 18 aortic aneurysm patients, each with two CT scans (arterial contrast phase, electrocardiogram-gated) with an interval of at least six months have been included. One board-certified radiologist and two residents (8/4/2 years of experience in vascular imaging) independently assessed aortic diameters at nine landmark positions. Aneurysm extensions were compared with original CT reports. After three weeks washout period, CTs were re-assessed, based on graphically illustrated AI measurements.

Results: Time-consuming guideline-compliant aortic measurements revealed additional affections of the root / arch for 80 % of aneurysms that had initially been reported to be limited to the ascending aorta. AI assistance reduced mean reporting time by 63 % from 13:01 to 04:46 min including manual corrections of AI measurements (performed for 33.6 % of all measurements with predominance at the sinuses of Vasalva). AI assistance reduced total diameter inter-reader variability by 42.5 % (0.42 / 1.16 mm with / without AI assistance, mean of all patients and landmark positions, significant reduction for 6 out of 9 measuring positions). Conventional and AI-assisted quantification aneurysm progress varied to small extent (mean of 0.75 mm over all patients / landmark positions) not significantly exceeding radiologist's inter-reader variabilities.

Conclusions: Guideline-compliant aorta measurement is crucial to report detailed aneurysm extension which might affect the strategy of interventional repair. AI assistance promises improved reporting efficiency and has high potential to reduce radiologist's inter-reader variabilities that can hamper diagnostic follow-up accuracy.

Key point: The time-consuming guideline-compliant aorta aneurysm assessment is crucial to report aneurysm extension in detail; AI-assisted measurement reduces reporting time, improves extension evaluation and reduces inter-reader variability.

Keywords: Aneurysm; Aorta; Artificial intelligence; Computed Tomography; Thoracic.

PubMed Disclaimer

LinkOut - more resources