Splenic blood flow measurements by Doppler ultrasound: a preliminary report
- PMID: 3326675
- DOI: 10.1093/cvr/21.10.779
Splenic blood flow measurements by Doppler ultrasound: a preliminary report
Abstract
Splenic blood flow and splenic volume were measured by Doppler and cross sectional ultrasound in 72 human subjects consisting of 61 patients with splenomegaly and 11 normal subjects. This non-invasive and relatively simple method yielded satisfactory results in 76% of the subjects studied; failures were due to obesity, debility, distorted vascular anatomy, and excessive gas in the stomach. These preliminary results suggest that the Doppler ultrasound technique is a practical clinical method for measuring splenic blood flow.
Similar articles
-
Splenic blood flow and intrasplenic platelet kinetics in relation to spleen volume.Br J Haematol. 1987 Oct;67(2):181-5. doi: 10.1111/j.1365-2141.1987.tb02324.x. Br J Haematol. 1987. PMID: 3676106
-
Partially reversed intrasplenic venous blood flow detected by color Doppler sonography in two patients with hematologic diseases and splenomegaly.J Clin Ultrasound. 2001 Jun;29(5):294-7. doi: 10.1002/jcu.1037. J Clin Ultrasound. 2001. PMID: 11486325
-
Splenic irradiation provides transient palliation for symptomatic splenomegaly associated with primary myelofibrosis: a report on 14 patients.Int J Hematol. 2016 Apr;103(4):423-8. doi: 10.1007/s12185-016-1940-3. Epub 2016 Jan 20. Int J Hematol. 2016. PMID: 26791378
-
Unusual renal displacement due to massive splenomegaly: a rare case report and review of literature.J Int Med Res. 2024 Sep;52(9):3000605241279812. doi: 10.1177/03000605241279812. J Int Med Res. 2024. PMID: 39308223 Free PMC article. Review.
-
Splenic irradiation in myelofibrosis with myeloid metaplasia: a review.Blood Rev. 1999 Sep;13(3):163-70. doi: 10.1054/blre.1999.0110. Blood Rev. 1999. PMID: 10527268 Review.
Cited by
-
Emerging Role of the Spleen in the Pharmacokinetics of Monoclonal Antibodies, Nanoparticles and Exosomes.Int J Mol Sci. 2017 Jun 10;18(6):1249. doi: 10.3390/ijms18061249. Int J Mol Sci. 2017. PMID: 28604595 Free PMC article. Review.
-
Quantification of human splenic blood flow (quantitative measurement of splenic blood flow with H2(15)O and a dynamic state method: 1).Ann Nucl Med. 1993 Nov;7(4):245-50. doi: 10.1007/BF03164705. Ann Nucl Med. 1993. PMID: 8292450
-
The cardiosplenic axis: the prognostic role of the spleen in heart failure.Heart Fail Rev. 2022 Nov;27(6):2005-2015. doi: 10.1007/s10741-022-10248-4. Epub 2022 May 18. Heart Fail Rev. 2022. PMID: 35583622 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources