Clinical applications of miniscrews that broaden the scope of non-surgical orthodontic treatment
- PMID: 33275826
- DOI: 10.1111/ocr.12452
Clinical applications of miniscrews that broaden the scope of non-surgical orthodontic treatment
Abstract
Previously, in the case of malocclusion owing to skeletal discrepancy in adults, the amount of tooth movement was limited since there was no reliable skeletal anchorage device. The only way to treat this case was by repositioning the maxilla and mandible via orthognathic surgery, but most patients are reluctant to undergo surgery owing to the risk and expenses incurred. However, with the current introduction and use of miniscrews as temporary anchorage devices, the entire dental arch can be relocated to a target position without surgery, thus broadening the scope of non-surgical orthodontic treatment compared to the past. For a non-surgical approach to improve skeletal discrepancy, anteroposterior, vertical and transverse displacements of the dental arch are necessary. In this case, the localization of the centre of resistance of the whole arch must precede the appliance design with an appropriate biomechanical design. Especially, in the transverse dimension, the envelope of discrepancy is reportedly narrow, and the tooth movement must accompany the orthopaedic correction involving the midpalatal suture expansion. Recently, in adults with transverse maxillomandibular discrepancy, miniscrew-assisted rapid palatal expansion (MARPE) can be performed. Moreover, compared to surgically assisted rapid palatal expansion, MARPE reduces the cost to the patient and achieves clinically acceptable stable maxillary expansion. In this article, we will discuss the role of total arch movement and MARPE in widening the scope of non-surgical orthodontic treatment, despite the inherent limitations of miniscrews' mechanical aspects.
Keywords: MARPE; total arch distalization; total arch intrusion; transverse maxillary deficiency.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
References
REFERENCES
-
- Galli C, Piemontese M, Ravanetti F, et al. Effect of surface treatment on cell responses to grades 4 and 5 titanium for orthodontic mini-implants. Am J Orthod Dentofacial Orthop. 2012;141:705-714.
-
- Suzuki M, Deguchi T, Watanabe H, et al. Evaluation of optimal length and insertion torque for miniscrews. Am J Orthod Dentofacial Orthop. 2013;144:251-259.
-
- Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 2012;142(5):577-595.e7.
-
- Watanabe H, Deguchi T, Hasegawa M, Ito M, Kim S, Takano-Yamamoto T. Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density. Orthod Craniofac Res. 2013;16:44-55.
-
- Chen Y, Kyung HM, Zhao WT, Yu WJ. Critical factors for the success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop. 2009;135:284-291.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous