Review
. 2021 May 1;47(5):655-661.
doi: 10.1097/j.jcrs.0000000000000508.

Role of rheology in tears and artificial tears

Affiliations
Review

Role of rheology in tears and artificial tears

Steve A Arshinoff et al. J Cataract Refract Surg. .

Abstract

The study of viscoelastic fluids as artificial tears dates back to the late 1970s. Healon, the first ophthalmic viscosurgical device, was approved in 1980, but studied extensively before then, exhibits very interesting shear-thinning properties that were found to be beneficial in both ophthalmic surgery and somewhat later as a tear replacement solution. Unlike the previous tear film replacements, which were mainly viscous in nature, viscoelastic solutions, particularly those based on hyaluronan, exhibited very interesting, potentially beneficial, rheological properties, especially when slightly altered to become elastoviscous. This review examines the rheological properties that are significant in artificial tear solutions. We define herein the necessary parameters that need to be further studied to design and formulate rheologically better artificial tears, which should provide enhanced efficacy compared with their predecessors.

PubMed Disclaimer

References

    1. Liesegang TJ. Viscoelastic substances in ophthalmology. Surv Ophthalmol 1990;34:268–293
    1. Arshinoff SA, Berk TA, Using ophthalmic viscosurgical devices to manage problems in cataract surgery. In: Fishkind WJ, ed. Section XII, ch.33 Phacoemulsification and Intraocular Lens Implantation: Mastering Techniques and Complications in Cataract Surgery. 2nd ed. New York, NY: Thieme Publishers; 2017:277–290
    1. Polack FM, McNiece MT. The treatment of dry eyes with Na-hyaluronate (Healon). Cornea 1982;1:133–136
    1. Arshinoff SA. Viscoelastic substances: their properties and use when placing an IOL in the capsular bag. Curr Cdn Ophthal Pract 1986;4:64–65
    1. Arshinoff SA, Norman R. Tri-soft shell technique. J Cataract Refract Surg 2013;39:1196–1203