. 2021 Feb 1;35(2):391-403.
doi: 10.1519/JSC.0000000000003864.

Ergogenic and Physiological Outcomes Derived From a Novel Skin Cooling Device

Affiliations

Ergogenic and Physiological Outcomes Derived From a Novel Skin Cooling Device

William D Gray et al. J Strength Cond Res. .

Abstract

Gray, WD, Jett, DM, Cocco, AR, Vanhoover, AC, Colborn, CE, Pantalos, GM, Stumbo, J, Quesada, PM, and Caruso, JF. Ergogenic and physiological outcomes derived from a novel skin cooling device. J Strength Cond Res 35(2): 391-403, 2021-Our study's purpose assessed a cooling headband's ergogenic and physiological impacts. Subjects (15 women and 13 men) completed six visits; the final 3 entailed rowing workouts with the following treatment conditions: no head cooling (NoHC), intermittent head cooling during exercise (HCex), and intermittent head cooling during exercise and post-exercise recovery (HCex&post). Data collection occurred at the following times (a) pre-exercise and post-warm-up, (b) between stages of up to eight 2-minute bouts, and (c) at 5, 10, 15, and 20 minutes post-exercise. In addition to distance rowed, thermal, cardiovascular, perceptual, and metabolic measurements were obtained. Results included a small yet significant intertreatment difference (HCex, HCex&post > NoHC) for distance rowed. Our cardiovascular and metabolic indices exhibited sex and time differences but likely did not contribute to the ergogenic effect. Yet, left hand temperatures (LHT) exhibited significant 2-way and 3-way interactions that were the likely source of the ergogenic effect. Auditory canal temperature (AUDT) results suggest the head is sensitive to heat increases, yet LHT data show headband use evoked significantly greater temperature increases at the hand's palmar surface, indicative of heat transfer. We conclude, and our practical applications suggest, the headband's ergogenic effect was manifested by cold-induced vasodilation at the hand's palmar surface, rather than heat losses through the head.

PubMed Disclaimer

References

    1. Bongers CCWG, Thijssen DHJ, Veltmeijer MTW, Hopman MT, Eljsvogels TM. Precooling and percooling (cooling during exercise) both improve performance in the heat: A meta-analytical review. Br J Sports Med 49: 377–384, 2015.
    1. Cabanac M, White MD. Core temperature thresholds for hyperpnea during passive hyperthermia in humans. Eur J Appl Physiol 71: 71–76, 1995.
    1. Caruso JF, Barbosa AG, Erickson L, et al. Intermittent palm cooling's impact on resistive exercise performance. Int J Sports Med 36: 814–821, 2015.
    1. Chan APC, Yang Y, Wong FKW, Yam MCH. Reduction of physiological strain under a hot and humid environment by a hybrid cooling vest. J Strength Cond Res 33: 1429–1436, 2019.
    1. DeGroot DW, Gallimore RP, Thompson SM, Kenefick RW. Extremity cooling for heat stress mitigation in the military and occupational settings. J Therm Biol 38: 305–310, 2013.

Substances

LinkOut - more resources