Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jul;36(7S):S290-S294.e1.
doi: 10.1016/j.arth.2020.11.015. Epub 2020 Nov 16.

Artificial Intelligence to Identify Arthroplasty Implants From Radiographs of the Hip

Affiliations

Artificial Intelligence to Identify Arthroplasty Implants From Radiographs of the Hip

Jaret M Karnuta et al. J Arthroplasty. 2021 Jul.

Abstract

Background: The surgical management of complications surrounding patients who have undergone hip arthroplasty necessitates accurate identification of the femoral implant manufacturer and model. Failure to do so risks delays in care, increased morbidity, and further economic burden. Because few arthroplasty experts can confidently classify implants using plain radiographs, automated image processing using deep learning for implant identification may offer an opportunity to improve the value of care rendered.

Methods: We trained, validated, and externally tested a deep-learning system to classify total hip arthroplasty and hip resurfacing arthroplasty femoral implants as one of 18 different manufacturer models from 1972 retrospectively collected anterior-posterior (AP) plain radiographs from 4 sites in one quaternary referral health system. From these radiographs, 1559 were used for training, 207 for validation, and 206 for external testing. Performance was evaluated by calculating the area under the receiver-operating characteristic curve, sensitivity, specificity, and accuracy, as compared with a reference standard of implant model from operative reports with implant serial numbers.

Results: The training and validation data sets from 1715 patients and 1766 AP radiographs included 18 different femoral components across four leading implant manufacturers and 10 fellowship-trained arthroplasty surgeons. After 1000 training epochs by the deep-learning system, the system discriminated 18 implant models with an area under the receiver-operating characteristic curve of 0.999, accuracy of 99.6%, sensitivity of 94.3%, and specificity of 99.8% in the external-testing data set of 206 AP radiographs.

Conclusions: A deep-learning system using AP plain radiographs accurately differentiated among 18 hip arthroplasty models from four industry leading manufacturers.

Keywords: artificial intelligence; implant identification; machine learning; revision arthroplasty; total hip arthroplasty.

PubMed Disclaimer

Comment in

LinkOut - more resources