Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Feb 1;223(Pt 1):121795.
doi: 10.1016/j.talanta.2020.121795. Epub 2020 Oct 21.

Direct solid sampling for speciation of Zn2+ and ZnO nanoparticles in cosmetics by graphite furnace atomic absorption spectrometry

Affiliations
Free article

Direct solid sampling for speciation of Zn2+ and ZnO nanoparticles in cosmetics by graphite furnace atomic absorption spectrometry

J C García-Mesa et al. Talanta. .
Free article

Abstract

The application of nanoparticles (NPs) in science and technology is a fast growing field. Therefore, reliable and straightforward analytical methods are required for their fast determination in different types of samples. This work investigates a method that enables the determination of ZnO NPs, discriminating them from ionic zinc in cosmetic samples. The method is based on direct solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry (SS-HR-CS-GFAAS), and has been applied to determination of ZnO NPs, Zn2+ and total Zn in eye shadow samples. In this work the deconvolution of the atomization peak and the calibration by standard additions have been done in order to discriminate and quantify ionic zinc and ZnO NPs. A Zn wavelength with low sensitivity was selected. The proper optimization of the graphite furnace temperature program, minimizing the mineralization of the sample matrix, enables different atomization profiles between the different chemical species of the analyte. Two multiple response surface designs have been used in order to optimize the adequate furnace program to achieve our aims. All the optimization experiments were performed using a sample of eye shadow. Further, a method for the determination of total Zn by direct solid sampling with calibration by aqueous standards, was also optimized. The optimized method was successfully applied to the determination of ionic Zn and ZnO NPs in different eye shadow samples, and has been validated by recovery assays, obtaining recovery percentages between 80 and 125%. Total Zn concentration in the solid samples was validated by the determination of total Zn by direct solid sampling and by the analysis of the same eye shadow samples digested in microwave oven.

Keywords: Direct solid sampling; Eye shadow; HR-CS-GFAAS; ZnO nanoparticles.

PubMed Disclaimer

LinkOut - more resources