Integration of three-dimensional echocardiography into the modern-day echo laboratory
Abstract
Three-dimensional echocardiography (3DE) has emerged in recent decades from a conceptual, research tool to an important, useful imaging technique that can informatively impact daily clinical practice. However, its adoption into the modern-day echo laboratory requires the acknowledgment of its value, coupled with proper leadership, education, and resources to implement and integrate its use with conventional echo techniques. 3DE integration involves important updates regarding equipment and patient selection, assimilation of 3D protocols into current clinical routine, laboratory workflow adaptation, storage, and reporting. This review will provide a practical blueprint and key points of how to integrate 3DE into today's echo laboratory, necessary resources to implement 3D workflow, logistical challenges that remain, and future directions to further improve assimilation of this relevant echo technique into the laboratory.
Keywords: cardiac imaging; three-dimensional echocardiography; three-dimensional transesophageal echocardiography; three-dimensional transthoracic echocardiography.
© 2020 Wiley Periodicals LLC.
Comment in
-
Current impact of three-dimensional echocardiography.Echocardiography. 2022 Jul;39(7):1010. doi: 10.1111/echo.15051. Echocardiography. 2022. PMID: 35891581 No abstract available.
References
REFERENCES
-
- Morbach C, Lin BA, Sugeng L. Clinical application of three-dimensional echocardiography. Prog Cardiovasc Dis. 2014;57:19-31.
-
- Dorosz JL, Lezotte DC, Weitzenkamp DA, et al Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. J Am Coll Cardiol. 2012;59:1799-1808.
-
- Thavendiranathan P, Liu S, Verhaert D, et al Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation. JACC Cardiovasc Imaging. 2012;5:239-251.
-
- Thavendiranathan P, Grant AD, Negishi T, et al Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy. J Am Coll Cardiol. 2013;61:77-84.
-
- Sugeng L, Shernan SK, Weinert L, et al Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves. J Am Soc Echocardiogr. 2008;21:1347-1354.