. 2021 May;18(5):752-759.
doi: 10.1016/j.hrthm.2020.12.011. Epub 2020 Dec 13.

Staphylococcus bacteremia without evidence of cardiac implantable electronic device infection

Affiliations

Staphylococcus bacteremia without evidence of cardiac implantable electronic device infection

Ikutaro Nakajima et al. Heart Rhythm. 2021 May.

Abstract

Background: Staphylococcus bacteremia (SB) in the presence of a cardiac implantable electronic device (CIED) is frequently associated with CIED infection. In patients without clear CIED infection but SB, the role of empirical CIED removal is unclear.

Objective: The purpose of this study was to describe the natural history of SB in the setting of a CIED and the effect of CIED removal on mortality in patients with concurrent SB without evidence of CIED infection.

Methods: Three hundred sixty consecutive patients (mean age 61 ± 17 years; 255 (71%) men; 329 (92%) Staphylococcus aureus) with a CIED and concurrent SB were reviewed.

Results: At the initial presentation with SB, 178 patients had no evidence of CIED infection. Of these, 132 (74%) had another identified source of infection. Among the 178 patients without CIED infection, 18 (10%) had empirical CIED removal during the initial bacteremia. Among those who did not undergo CIED removal, SB subsequently relapsed in 19% and relapse rates were not different for those with or without another identifiable source at the initial presentation. Relapse was strongly associated with the duration of SB >1 day (odds ratio 9.99; 95% confidence interval 3.24-30.86). Despite the absence of CIED infection, 1-year mortality was 35% and empirical device removal during the initial presentation was associated with survival benefit (hazard ratio 0.28; 95% confidence interval 0.08-0.95).

Conclusion: For patients with SB without evidence of CIED infection, relapse is predicted by the duration of bacteremia. Empirical CIED removal appears to be associated with a survival benefit, although there are likely clinical situations in which this could be deferred.

Keywords: Bacteremia; Cardiac implantable electronic device; Coagulase-negative staphylococci; Device removal; Staphylococcus aureus.

PubMed Disclaimer

Comment in

  • Fighting the invisible enemy.
    Tarakji KG. Tarakji KG. Heart Rhythm. 2021 May;18(5):760-761. doi: 10.1016/j.hrthm.2021.01.024. Epub 2021 Jan 27. Heart Rhythm. 2021. PMID: 33515715 No abstract available.

Publication types

LinkOut - more resources