Multicenter Evaluation of the Unyvero Platform for Testing Bronchoalveolar Lavage Fluid
- PMID: 33328178
- PMCID: PMC8106704
- DOI: 10.1128/JCM.02497-20
Multicenter Evaluation of the Unyvero Platform for Testing Bronchoalveolar Lavage Fluid
Abstract
Bronchoalveolar lavage (BAL) culture is a standard, though time-consuming, approach for identifying microorganisms in patients with severe lower respiratory tract (LRT) infections. The sensitivity of BAL culture is relatively low, and prior antimicrobial therapy decreases the sensitivity further, leading to overuse of empirical antibiotics. The Unyvero LRT BAL Application (Curetis GmbH, Germany) is a multiplex molecular panel that detects 19 bacteria, 10 antibiotic resistance markers, and a fungus, Pneumocystis jirovecii, in BAL fluid in ∼4.5 h. Its performance was evaluated using 1,016 prospectively collected and 392 archived specimens from 11 clinical trial sites in the United States. Overall positive and negative percent agreements with culture results for identification of bacteria that grow in routine cultures were 93.4% and 98.3%, respectively, with additional potential pathogens identified by Unyvero in 21.7% of prospectively collected specimens. For detection of P. jirovecii, the positive percent agreement with standard testing was 87.5%. Antibiotic resistance marker results were compared to standard antibiotic susceptibility test results to determine positive predictive values (PPVs). PPVs ranged from 80 to 100%, based on the microorganism and specific resistance marker(s). The Unyvero LRT BAL Application provides accurate detection of common agents of bacterial pneumonia and of P. jirovecii The sensitivity and rapidity of this panel suggest significant clinical value for choosing appropriate antibiotics and for antibiotic stewardship.
Keywords: BAL; molecular diagnostics; multiplex PCR; pneumonia.
Copyright © 2021 American Society for Microbiology.
Similar articles
-
Comparison of Unyvero P55 Pneumonia Cartridge, in-house PCR and culture for the identification of respiratory pathogens and antibiotic resistance in bronchoalveolar lavage fluids in the critical care setting.Eur J Clin Microbiol Infect Dis. 2019 Jun;38(6):1171-1178. doi: 10.1007/s10096-019-03526-x. Epub 2019 Mar 11. Eur J Clin Microbiol Infect Dis. 2019. PMID: 30859358
-
An evaluation of the Unyvero pneumonia system for rapid detection of microorganisms and resistance markers of lower respiratory infections-a multicenter prospective study on ICU patients.Eur J Clin Microbiol Infect Dis. 2021 Oct;40(10):2113-2121. doi: 10.1007/s10096-021-04259-6. Epub 2021 May 1. Eur J Clin Microbiol Infect Dis. 2021. PMID: 33934275
-
Usefulness of point-of-care multiplex PCR to rapidly identify pathogens responsible for ventilator-associated pneumonia and their resistance to antibiotics: an observational study.Crit Care. 2020 Jun 26;24(1):378. doi: 10.1186/s13054-020-03102-2. Crit Care. 2020. PMID: 32586347 Free PMC article.
-
Impact of Multiplex PCR in the Therapeutic Management of Severe Bacterial Pneumonia.Antibiotics (Basel). 2024 Jan 18;13(1):95. doi: 10.3390/antibiotics13010095. Antibiotics (Basel). 2024. PMID: 38247654 Free PMC article. Review.
-
Breaking Boundaries in Pneumonia Diagnostics: Transitioning from Tradition to Molecular Frontiers with Multiplex PCR.Diagnostics (Basel). 2024 Apr 2;14(7):752. doi: 10.3390/diagnostics14070752. Diagnostics (Basel). 2024. PMID: 38611665 Free PMC article. Review.
Cited by
-
Next-generation molecular diagnostics: Leveraging digital technologies to enhance multiplexing in real-time PCR.Trends Analyt Chem. 2023 Mar;160:116963. doi: 10.1016/j.trac.2023.116963. Epub 2023 Feb 9. Trends Analyt Chem. 2023. PMID: 36968318 Free PMC article.
-
ERS/ESICM/ESCMID/ALAT guidelines for the management of severe community-acquired pneumonia.Intensive Care Med. 2023 Jun;49(6):615-632. doi: 10.1007/s00134-023-07033-8. Epub 2023 Apr 4. Intensive Care Med. 2023. PMID: 37012484 Free PMC article.
-
Laboratory detection of carbapenemases among Gram-negative organisms.Clin Microbiol Rev. 2024 Dec 10;37(4):e0005422. doi: 10.1128/cmr.00054-22. Epub 2024 Nov 15. Clin Microbiol Rev. 2024. PMID: 39545731 Review.
-
Multiplex PCR for Microbiological Testing in Patients with Peritoneal Dialysis- and Liver Cirrhosis-Related Peritonitis: Faster, but Less Sensitive.J Clin Med. 2025 Apr 11;14(8):2641. doi: 10.3390/jcm14082641. J Clin Med. 2025. PMID: 40283471 Free PMC article.
-
The role of rapid multiplex molecular syndromic panels in the clinical management of infections in critically ill patients: an experts-opinion document.Crit Care. 2024 Dec 30;28(1):440. doi: 10.1186/s13054-024-05224-3. Crit Care. 2024. PMID: 39736683 Free PMC article. Review.
References
-
- Del Rio-Pertuz G, Gutiérrez JF, Triana AJ, Molinares JL, Robledo-Solano AB, Meza JL, Ariza-Bolívar OM, Acosta-Reyes J, Garavito A, Viasus D, Carratalà J. 2019. Usefulness of sputum gram stain for etiologic diagnosis in community-acquired pneumonia: a systematic review and meta-analysis. BMC Infect Dis 19:403. doi:10.1186/s12879-019-4048-6. - DOI - PMC - PubMed
-
- Fernando SM, Tran A, Cheng W, Klompas M, Kyeremanteng K, Mehta S, English SW, Muscedere J, Cook DJ, Torres A, Ranzani OT, Fox-Robichaud AE, Alhazzani W, Munshi L, Guyatt GH, Rochwerg B. 2020. Diagnosis of ventilator-associated pneumonia in critically ill adult patients—a systematic review and meta-analysis. Intensive Care Med 46:1170–1179. doi:10.1007/s00134-020-06036-z. - DOI - PMC - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources