Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
[Preprint]. 2020 Dec 11:2020.12.10.20244301.
doi: 10.1101/2020.12.10.20244301.

SCENTinel 1.0 : development of a rapid test to screen for smell loss

SCENTinel 1.0 : development of a rapid test to screen for smell loss

Valentina Parma et al. medRxiv. .

Update in

Abstract

Background: Commercially available smell tests are primarily used in research or in-depth clinical evaluations, but are too costly and lengthy for population surveillance in health emergencies like COVID-19. We developed the SCENTinel 1 . 0 test which rapidly evaluates three olfactory functions (detection, intensity, and identification). We tested whether self-administering the SCENTinel 1 . 0 test discriminates between individuals with smell loss or average smell ability (normosmics), and provides comparable performance as the validated and standardized NIH Toolbox ® Odor Identification Test in normosmics.

Methods: Using Bayesian linear models and prognostic classification algorithms, we compared the SCENTinel 1 . 0 performance of a group of self-reported anosmics (N=111, 47±13yo, F=71%,) and normosmics (N=154, 47±14yo, F=74%), as well as individuals reporting other smell disorders (e.g., hyposmia, parosmia; N=42, 55±10yo, F=67%).

Results: Ninety-four percent of normosmics met our SCENTinel 1 . 0 accuracy criteria, while only 10% of anosmics and 64% of individuals with other smell disorders did. Overall performance on SCENTinel 1 . 0 predicted belonging to the normosmic group better than identification or detection alone (vs. anosmic: AUC=0.95, Sensitivity=0.72, Specificity=0.94). Odor intensity provided the best single-feature predictor to classify normosmics. Among normosmics, 92% met the accuracy criteria at both SCENTinel 1 . 0 and the NIH Toolbox ® Odor Identification Test.

Conclusions: SCENTinel 1 . 0 is a practical test able to discriminate individuals with smell loss and is likely to be useful in many clinical situations, including COVID-19 symptom screening.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources