Aging behavior of high-translucent CAD/CAM resin-based composite blocks
- PMID: 33341738
- DOI: 10.1016/j.jmbbm.2020.104269
Aging behavior of high-translucent CAD/CAM resin-based composite blocks
Abstract
Objective: The aim of this study was to investigate the influence of artificial aging on the mechanical properties and fracture patterns of novel CAD/CAM resin-based composite blocks (RCB).
Methods: Flexural strength and modulus of RCBs from seven manufacturers (Voco, Grandio Blocs, GB; Ivoclar Vivadent, Tetric®CAD, TC; DMG, Luxacam Composite, LC; Shofu Block HC, SF; 3M, Lava™ Ultimate, LU; GC, Cerasmart®, CS; Coltene, BRILLIANT Crios, CB) were assessed in a three-point-bending test after an aging process consisting of three sequential steps (14 days storage in artificial saliva, 10,000 thermo-cycles in distilled water between 5/55 °C, 48 h storage in ethanol 75%). Fracture origins were determined in a fractographic examination using reflected light stereomicroscopy combined with transillumination and scanning electron microscopy. Effects of aging were statistically analysed using one-way ANOVA with Tukey's HSD post hoc test (α = 0.05) and Weibull statistics. Correlations regarding filler amount were analysed using linear regression analysis.
Results: The strongest influence on the flexural modulus and strength was exerted based on the parameter material (p < 0.001, ɳP2 = 0.957; ɳP2 = 0.770), but the influence of in vitro aging was also significant (p < 0.001, ɳP2 = 0.623; ɳP2 = 0.407). Storage in artificial saliva decreased the flexural modulus and flexural strength of all materials, apart from CS, significantly (p < 0.05). The Weibull moduli varied from 5.8 to 22.4. Filler amount correlated significantly with flexural modulus (p < 0.001; R2 = 0.739). Fractography revealed four different fracture patterns with fracture origins from the corner, edge or sub-surface and a smooth fracture surface with non-identifiable fracture origin. Specimens with smooth fracture surface showed the significantly lowest flexural strength (p < 0.001). Pores, agglomerates and inclusions were identified as fracture origins.
Conclusions: Storage in artificial saliva mainly reduced the mechanical properties significantly while additional thermal aging mostly maintained the results. Aging in ethanol mostly maintained the results for flexural modulus but led to an increase in flexural strength values to the level of the unaged specimens. Fractographic analysis revealed a significant accumulation of sub-surface fracture origins after storage in ethanol arising from inherent flaws.
Keywords: Artificial aging; Biomedical material; CAD/CAM resin-based composite; Fractographic analysis; Mechanical properties; Weibull analysis.
Copyright © 2020 Elsevier Ltd. All rights reserved.
Similar articles
-
Fracture Toughness, Flexural Strength, and Flexural Modulus of New CAD/CAM Resin Composite Blocks.J Prosthodont. 2020 Jan;29(1):34-41. doi: 10.1111/jopr.13123. Epub 2019 Nov 19. J Prosthodont. 2020. PMID: 31702090
-
Flexural resistance of CAD-CAM blocks. Part 3: Polymer-based restorative materials for permanent restorations.Am J Dent. 2020 Oct;33(5):243-247. Am J Dent. 2020. PMID: 33017526
-
Fracture force of CAD/CAM resin composite crowns after in vitro aging.Clin Oral Investig. 2020 Jul;24(7):2395-2401. doi: 10.1007/s00784-019-03099-1. Epub 2019 Nov 11. Clin Oral Investig. 2020. PMID: 31712983
-
Resin Composite Materials for Chairside CAD/CAM Restorations: A Comparison of Selected Mechanical Properties.J Healthc Eng. 2021 Apr 28;2021:8828954. doi: 10.1155/2021/8828954. eCollection 2021. J Healthc Eng. 2021. PMID: 34007429 Free PMC article.
-
Methods for evaluating fracture patterns of polycrystalline materials based on the parameter analysis of fatigue striations: A review.MethodsX. 2024 Oct 11;13:102989. doi: 10.1016/j.mex.2024.102989. eCollection 2024 Dec. MethodsX. 2024. PMID: 39687591 Free PMC article. Review.
Cited by
-
Effects of food-simulating solutions on the surface properties of two CAD/CAM resin composites.J Clin Exp Dent. 2022 Oct 1;14(10):e782-e790. doi: 10.4317/jced.59822. eCollection 2022 Oct. J Clin Exp Dent. 2022. PMID: 36320679 Free PMC article.
-
Cenospheres-Reinforced PA-12 Composite: Preparation, Physicochemical Properties, and Soaking Tests.Polymers (Basel). 2022 Jun 9;14(12):2332. doi: 10.3390/polym14122332. Polymers (Basel). 2022. PMID: 35745908 Free PMC article.
-
Evaluation of Physical-Chemical Properties of Contemporary CAD/CAM Materials with Chromatic Transition "Multicolor".Materials (Basel). 2023 Jun 5;16(11):4189. doi: 10.3390/ma16114189. Materials (Basel). 2023. PMID: 37297323 Free PMC article.
-
Shade, Aging and Spatial-Dependent Variation of Elastoplastic and Viscoelastic Characteristics in a Dental, Submicron Hybrid CAD/CAM Composite.Materials (Basel). 2023 Aug 17;16(16):5654. doi: 10.3390/ma16165654. Materials (Basel). 2023. PMID: 37629945 Free PMC article.
-
Influence of dental prophylaxis procedures on the tooth veneer interface in resin-based composite and polymer-infiltrated ceramic veneer restorations: an in vitro study.Clin Oral Investig. 2023 Jun;27(6):2595-2607. doi: 10.1007/s00784-022-04816-z. Epub 2022 Dec 11. Clin Oral Investig. 2023. PMID: 36502509 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous