Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar:145:111202.
doi: 10.1016/j.exger.2020.111202. Epub 2020 Dec 19.

Validity, reliability, and measurement error of a sit-to-stand power test in older adults: A pre-registered study

Affiliations

Validity, reliability, and measurement error of a sit-to-stand power test in older adults: A pre-registered study

Anoop T Balachandran et al. Exp Gerontol. 2021 Mar.

Abstract

Objectives: Lower body power declines with age and is associated with decreased physical function in older adults. However, the majority of the tools available to measure power are expensive and require considerable space and expertise to operate. The purpose of this study was to assess the validity, reliability, and measurement error of a sit-to-stand power test (STSp) to assess lower body power.

Methods: 51 community-dwelling adults, 65 years or older, completed a power test using a pneumatic leg press (LP), the Short Physical Performance Battery (SPPB) that includes a test of balance, usual walking speed, and chair stand tests; Timed Up and Go (TUG) test at both usual and fast paces, and Patient-Reported Outcome Measures (PROMs). A two-week test-retest assessed the reliability in 36 participants. The study hypotheses and analysis were pre-registered prior to data collection and statistical analyses were blinded.

Results: The mean age was 71.3 years, with 63% females, and an average SPPB score of 10.6 (median = 12). STSp peak power was strongly correlated with LP (r = 0.90, 95% CI (0.82, 0.94). As hypothesized, the STSp peak power showed similar or higher correlations with physical function tests relative to LP peak power: SPPB (0.41 vs. 0.29), chair stand test (-0.44 vs. -0.35), TUG test at usual pace (-0.37 vs. -0.29) and fast pace (-0.41 vs. -0.34) and balance (0.33 vs. 0.22), but not for mobility (0.34 vs. 0.38) and function (0.41 vs. 0.48) questionnaire. For discriminant validity, as hypothesized, males showed higher STSp peak power compared to females (Δ = 492 W, p < .001, Cohen's d = 2.0). Test-retest assessment yielded an intraclass correlation coefficient of 0.96 and a standard error of measurement of 70.4 W. No adverse events were reported or observed for both tests.

Conclusion: The STSp showed adequate validity and reliability in measuring lower body power in community-dwelling older adults. The test is quick, relatively inexpensive, safe, and portable and thus should be considered for use in aging research.

Keywords: Aging; Elderly; Physical function; Power; Velocity.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources