Conjunctival oxygen tension monitoring during a controlled phlebotomy
- PMID: 3334794
- DOI: 10.1016/0735-6757(88)90196-9
Conjunctival oxygen tension monitoring during a controlled phlebotomy
Abstract
A decrease in the conjunctival oxygen tension (Pcjo2) and conjunctival index (Pcjo2/Pao2) has been shown to be an early marker of acute blood loss. We sequentially measured Pcjo2, Pcjo2/Pao2, blood pressure, and pulse rate in five healthy adults after controlled phlebotomy of 450 mL and after intravenous fluid repletion. No significant changes occurred in either the Pcjo2 or Pcjo2/Pao2 after phlebotomy or after fluid replacement. We conclude that a blood loss of 450 mL in healthy, euvolemic adults is insufficient to perturb the conjunctival index. The lower limits of sensitivity of changes in Pcjo2 and Pcjo/Pao2 in response to acute blood loss remain to be established.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources