Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jul;23(7):1084-1094.
doi: 10.1016/j.hpb.2020.11.005. Epub 2021 Jan 19.

Prediction of remnant liver volume using 3D simulation software in patients undergoing R1vasc parenchyma-sparing hepatectomy for multiple bilobar colorectal liver metastases: reliability, clinical impact, and learning curve

Affiliations
Free article

Prediction of remnant liver volume using 3D simulation software in patients undergoing R1vasc parenchyma-sparing hepatectomy for multiple bilobar colorectal liver metastases: reliability, clinical impact, and learning curve

Fabio Procopio et al. HPB (Oxford). 2021 Jul.
Free article

Abstract

Background: Assessment of the future liver remnant (FLR) is routinely performed before major hepatectomy. In R1-vascular one-stage hepatectomy (R1vasc-OSH), given the multiplanar dissection paths, the FLR is not easily predictable. Preoperative 3D-virtual casts may help. We evaluated the predictability of the FLR using the 3D-virtual cast in the R1vasc-OSH for multiple bilobar colorectal liver metastases (CLM).

Methods: Thirty consecutive patients with multiple bilobar CLMs scheduled for R1vasc-OSH were included. Predicted and real-FLRs were compared. Propensity score-matched analysis was used to determine the impact of 3D-virtual cast on postoperative complications.

Results: Median number of CLM and resection areas were 12 (4-33) and 3 (1-8). Median predicted-FLR was 899 ml (558-1157) and 60% (42-85), while for the real-FLR 915 ml (566-1777) and 63% (43-87). Median discrepancy between predicted and real-FLR was -0.6% (p = 0.504), indicating a slight tendency to underestimate the FLR. The difference was more evident in more than 12 CLMs (p = 0.013). A discrepancy was not evident according to the number of resection areas (p = 0.316). No mortality occurred. Patients in virtual-group had lower major complications compared to nonvirtual-group (0% vs 18%, p-value 0.014).

Conclusion: FLR estimation based on 3D-analysis is feasible, provides a safe surgery and represents a promising method in planning R1vasc-OSH for patients with multiple bilobar CLMs.

PubMed Disclaimer

LinkOut - more resources