Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component
- PMID: 33354829
- DOI: 10.1002/nbm.4449
Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component
Abstract
The aim of this study was to establish reference values for middle-aged subjects and to investigate the age and gender dependence of liver diffusion MRI parameters. The IVIM type of liver diffusion scan was based on a single-shot spin-echo-type echo-planar sequence using a 1.5 T magnet with 16 b-values. Diffusion-derived vessel density (DDVD)(b0b2) or DDVD(b0b10) was the signal difference between b = 0 and b = 2 (or b = 10) s/mm2 images after removing visible vessels. IVIM analysis was performed with full fitting and segmented fitting, and with a threshold b-value of 60 or 200 s/mm2 , and fitting started from b = 2 s/mm2 . Thirty-one men (age range: 25-71 years) and 26 men (age: 22-69 years) had DDVD and IVIM analysis, respectively, while 37 women (age: 20-71 years) and 36 women (age: 20-71 years) had DDVD and IVIM analysis, respectively. DDVD results showed a significant age-related reduction for women. IVIM results for full fitting showed excellent agreement with those for segmented fitting using a threshold b of 60 s/mm2 , but this was less good for results with a threshold b of 200 s/mm2 . As age increased, female subjects' Dslow measure showed a significant reduction, while their PF and Dfast measures showed a significant increase. For the age group of 40-55 years, DDVD(b0b2), DDVD(b0b10), Dslow , PF and Dfast were 12.26 ± 3.90 au/pixel, 16.95 ± 5.45 au/pixel, 1.072 ± 0.067 (10-3 mm2 /s), 0.141 ± 0.025 and 61.0 ± 14.0 (10-3 mm2 /s) for men, and 13.35 ± 3.6 au/pixel, 17.20 ± 3.62 au/pixel, 1.069 ± 0.074 (10-3 mm2 /s), 0.119 ± 0.014 and 57.1 ± 13.2 (10-3 mm2 /s) for women, respectively. DDVD measure of this study suggest that aging is associated with a reduction in liver perfusion. There is a possibility that a lower Dslow measure is associated with artificially higher PF and Dfast measures, and that IVIM modeling of the perfusion component is constrained by the diffusion component.
Keywords: aging; biophysical mechanisms of MR diffusion liver; diffusion-weighted imaging; hepatobiliary; intravoxel incoherent motion.
© 2020 John Wiley & Sons, Ltd.
References
REFERENCES
-
- Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology. 1986;161:401-407.
-
- Le Bihan D, Turner R, Moonen CT, Pekar J. Imaging of diffusion and microcirculation with gradient sensitization: design, strategy, and significance. J Magn Reson Imaging. 1991;1:7-28.
-
- Li YT, Cercueil JP, Yuan J, Chen W, Loffroy R, Wáng YX. Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. Quant Imaging Med Surg. 2017;7:59-78.
-
- Chevallier O, Zhou N, He J, Loffroy R, Wáng YX. Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan-rescan reproducibility. Acta Radiol. 2018;59:1157-1167.
-
- Wang YX. Living tissue intravoxel incoherent motion (IVIM) diffusion MR analysis without b=0 image: an example for liver fibrosis evaluation. Quant Imaging Med Surg. 2019;9:127-133.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials