Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar 31;67(4):610-620.
doi: 10.1093/clinchem/hvaa306.

Multiplex PCR and Nanopore Sequencing of Genes Associated with Antimicrobial Resistance in Neisseria gonorrhoeae Directly from Clinical Samples

Affiliations

Multiplex PCR and Nanopore Sequencing of Genes Associated with Antimicrobial Resistance in Neisseria gonorrhoeae Directly from Clinical Samples

Chi Zhang et al. Clin Chem. .

Abstract

Background: Antimicrobial resistance (AMR) of Neisseria gonorrhoeae has spread worldwide. Rapid and comprehensive methods are needed to describe N. gonorrhoeae AMR profiles accurately. A method based on multiplex amplicon sequencing was developed to simultaneously sequence 13 genes related to AMR in N. gonorrhoeae directly from clinical samples.

Methods: Nine N. gonorrhoeae strains were used for the establishment and validation of the method. Eleven urethral swabs and their corresponding cultured isolates were matched as pairs to determine the accuracy of the method. Mock samples with different dilutions were prepared to determine the sensitivity of the method. Five nongonococcal Neisseria strains and 24 N. gonorrhoeae negative clinical samples were used to evaluate the cross-reactivity. Finally, the method was applied to 64 clinical samples to assess its performance.

Results: Using Sanger sequencing as a reference method, sequences recovered from amplicon sequencing had a base accuracy of over 99.5% and the AMR sites were correctly identified. The limit of detection (LOD) was lower than 31 copies/reaction. No significant cross-reactivity was observed. Furthermore, target genes were successfully recovered from 64 clinical samples including 9 urines, demonstrating this method could be used in different types of samples. For clinical samples, the results can be obtained within a time frame of 7 h 40 min to 10 h 40 min, while for isolates, the turnaround time was approximately 2 h shorter.

Conclusions: This method can serve as a versatile and convenient culture-free diagnostic method with the advantages of high sensitivity and accuracy.

Keywords: Neisseria gonorrhoeae; Antimicrobial resistance; Multiplex amplicon sequencing; Targeted sequencing.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Substances