Deceleration area and capacity during labour-like umbilical cord occlusions identify evolving hypotension: a controlled study in fetal sheep
- PMID: 33369871
- DOI: 10.1111/1471-0528.16638
Deceleration area and capacity during labour-like umbilical cord occlusions identify evolving hypotension: a controlled study in fetal sheep
Abstract
Objective: Cardiotocography is widely used to assess fetal well-being during labour. The positive predictive value of current clinical algorithms to identify hypoxia-ischaemia is poor. In experimental studies, fetal hypotension is the strongest predictor of hypoxic-ischaemic injury. Cohort studies suggest that deceleration area and deceleration capacity of the fetal heart rate trace correlate with fetal acidaemia, but it is not known whether they are indices of fetal arterial hypotension.
Design: Prospective, controlled study.
Setting: Laboratory.
Sample: Near-term fetal sheep.
Methods: One minute of complete umbilical cord occlusions (UCOs) every 5 minutes (1:5 min, n = 6) or every 2.5 minutes (1:2.5 min, n = 12) for 4 hours or until fetal mean arterial blood pressure fell <20 mmHg.
Main outcome measures: Deceleration area and capacity during the UCO series were related to evolving hypotension.
Results: The 1:5 min group developed only mild metabolic acidaemia, without hypotension. By contrast, 10/12 fetuses in the 1:2.5-min group progressively developed severe metabolic acidaemia and hypotension, reaching 16.8 ± 0.9 mmHg after 71.2 ± 6.7 UCOs. Deceleration area and capacity remained unchanged throughout the UCO series in the 1:5-min group, but progressively increased in the 1:2.5-min group. The severity of hypotension was closely correlated with both deceleration area (P < 0.001, R2 = 0.66, n = 18) and capacity (P < 0.001, R2 = 0.67, n = 18). Deceleration area and capacity predicted development of hypotension at a median of 103 and 123 minutes before the final occlusion, respectively.
Conclusions: Both deceleration area and capacity were strongly associated with developing fetal hypotension, supporting their potential to improve identification of fetuses at risk of hypotension leading to hypoxic-ischaemic injury during labour.
Tweetable abstract: Deceleration area and capacity of fetal heart rate identify developing hypotension during labour-like hypoxia.
Keywords: Asphyxia; cardiotocography; computerised fetal heart rate monitoring; deceleration area; deceleration capacity; hypotension; hypoxia-ischaemia; phase-rectified signal averaging.
© 2021 John Wiley & Sons Ltd.
Comment in
-
Fetal cerebral perfusion is better than fetal acidaemia for the prediction of brain injury and might be assessable by sophisticated fetal heart rate metrics.BJOG. 2021 Aug;128(9):1443. doi: 10.1111/1471-0528.16674. Epub 2021 Mar 17. BJOG. 2021. PMID: 33666319 No abstract available.
References
-
- Parer JT, Ugwumadu A. Impediments to a unified international approach to the interpretation and management of intrapartum cardiotocographs. J Matern Fetal Neonatal Med 2017;30:272-3.
-
- Vintzileos AM, Smulian JC. Decelerations, tachycardia, and decreased variability: have we overlooked the significance of longitudinal fetal heart rate changes for detecting intrapartum fetal hypoxia? Am J Obstet Gynecol 2016;215:261-4.
-
- Alfirevic Z, Devane D, Gyte GM, Cuthbert A. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev. 2017;(2):CD006066.
-
- Nelson KB, Dambrosia JM, Ting TY, Grether JK. Uncertain value of electronic fetal monitoring in predicting cerebral palsy. N Engl J Med 1996;334:613-8.
-
- Thomas G, Blackwell RJ. The analysis of continuous fetal heart rate traces in the first and second stages of labour. BJOG 1975;82:634-42.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources