Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Aug;30(4):e13273.
doi: 10.1111/jsr.13273. Epub 2020 Dec 28.

Performance of an ambulatory electroencephalogram sleep monitor in patients with psychiatric disorders

Affiliations

Performance of an ambulatory electroencephalogram sleep monitor in patients with psychiatric disorders

Seiko Miyata et al. J Sleep Res. 2021 Aug.

Abstract

Key clinical symptoms observed among individuals with psychiatric disorders include difficulty falling asleep or maintaining sleep, poor sleep quality and nightmares. Those suffering from sleep disorders often present with symptoms of discontent with regard to sleep quality, timing and quantity, and these symptoms have an adverse impact on function and quality of life. A minimally invasive technique would be preferable in patients with psychiatric disorders, who tend to be sensitive to environmental change. Accordingly, we evaluated the performance of Zmachine Insight Plus, an ambulatory electroencephalography sleep monitor, in patients with psychiatric disorders. One hundred and three patients undergoing polysomnography were enrolled in this study. Zmachine Insight Plus was performed simultaneously with polysomnography. Total sleep time, sleep efficiency, wake after sleep onset, rapid eye movement (REM) sleep, light sleep (stages N1 and N2) and deep sleep (stage N3) were assessed. Total sleep time, sleep efficiency, wake after sleep onset, REM sleep duration and non-REM sleep duration of Zmachine Insight Plus showed a significant correlation with those of polysomnography. Lower sleep efficiency and increased frequency of waking after sleep onset, the arousal index and the apnea-hypopnea index on polysomnography were significantly associated with the difference in sleep parameters between the two methods. Among patients with psychiatric disorders who are sensitive to environmental change, Zmachine Insight Plus would be a useful technique to objectively evaluate sleep quality.

Keywords: polysomnography; portable EEG monitoring; psychiatric disorders; sleep disorders.

PubMed Disclaimer

References

REFERENCES

    1. American Academy of Sleep Medicine (2014). International classification of sleep disorders (3rd ed). American Academy of Sleep Medicine.
    1. Arbon, E. L., Knurowska, M., & Dijk, D. J. (2015). Randomised clinical trial of the effects of prolonged-release melatonin, temazepam and zolpidem on slow-wave activity during sleep in healthy people. Journal of Psychopharmacology, 29(7), 764-776. https://doi.org/10.1177/0269881115581963
    1. Becker, S. P., Sidol, C. A., Van Dyk, T. R., Epstein, J. N., & Beebe, D. W. (2017). Intraindividual variability of sleep/wake patterns in relation to child and adolescent functioning: A systematic review. Sleep Medicine Reviews, 34, 94-121. https://doi.org/10.1016/j.smrv.2016.07.004
    1. Berry, R. B., Brooks, R., Gamaldo, C. E., Harding, S. M., Marcus, C. L., & Vaughn, B. V. (2014). The AASM Manual for the scoring of sleep and associated events: Rules, terminology and technical specifications, version, 2.1. American Academy of Sleep Medicine.
    1. Bian, Y., Wang, Z. X., Han, X. L., Chen, L., Zhu, Y., & Wu, C. J. (2016). Sleep state misperception in schizophrenia: Are negative symptoms at work? Comprehensive Psychiatry, 67, 33-38. https://doi.org/10.1016/j.comppsych.2016.02.008

LinkOut - more resources