Heterophilic antibodies: a problem for all immunoassays
- PMID: 3338181
Heterophilic antibodies: a problem for all immunoassays
Abstract
We verified that antibody-binding substances in serum that interfere in two-site immunoassays involving murine antibodies are heterophilic antibodies. Incubation of serum containing heterophilic antibodies and a murine monoclonal antibody to human choriogonadotropin (hCG) leads to formation of a series of soluble immune complexes. We investigated the recognition of hCG by reagent antibody in the presence of heterophilic antibodies and found this recognition to be diminished. Consequently, about 30% of serum samples containing heterophilic antibodies falsely appear to contain increased concentrations of hCG. The effect on analyte recognition probably results from steric inhibition of hCG binding to complexed antibody. Heterophilic antibodies detected with a murine antibody also bound immunoglobulin from several other species but did not bind all of those tested.
Similar articles
-
Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test.JAMA. 1982 Nov 19;248(19):2489-90. JAMA. 1982. PMID: 6897083
-
Heterophilic antibodies against rabbit serum causing falsely elevated gonadotropin levels.Acta Obstet Gynecol Scand. 1989;68(4):377-8. doi: 10.3109/00016348909028676. Acta Obstet Gynecol Scand. 1989. PMID: 2515728
-
Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.Clin Biochem. 2016 Jun;49(9):729-731. doi: 10.1016/j.clinbiochem.2015.12.018. Epub 2016 Mar 9. Clin Biochem. 2016. PMID: 26968106
-
Heterophilic antibody interference in immunometric assays.Best Pract Res Clin Endocrinol Metab. 2013 Oct;27(5):647-61. doi: 10.1016/j.beem.2013.05.011. Epub 2013 Jun 20. Best Pract Res Clin Endocrinol Metab. 2013. PMID: 24094636 Review.
-
Antibody multispecificity in immunoassay interference.Clin Biochem. 1992 Apr;25(2):77-87. doi: 10.1016/0009-9120(92)80048-l. Clin Biochem. 1992. PMID: 1623581 Review.
Cited by
-
Interferences in immunoassay.Clin Biochem Rev. 2004 May;25(2):105-20. Clin Biochem Rev. 2004. PMID: 18458713 Free PMC article.
-
Effects of chronic leptin infusion on subsequent body weight and composition in mice: Can body weight set point be reset?Mol Metab. 2014 Mar 5;3(4):432-40. doi: 10.1016/j.molmet.2014.02.003. eCollection 2014 Jul. Mol Metab. 2014. PMID: 24944902 Free PMC article.
-
Subacute Cardiac Tamponade Due to Tuberculous Pericarditis Diagnosed by Urine Lipoarabinomannan Assay in a Immunocompetent Patient in Oyam District, Uganda: A Case Report.Int J Environ Res Public Health. 2022 Nov 17;19(22):15143. doi: 10.3390/ijerph192215143. Int J Environ Res Public Health. 2022. PMID: 36429861 Free PMC article.
-
False Positive Troponin Levels due to Heterophil Antibodies in a Pregnant Woman.Turk J Emerg Med. 2016 Mar 2;15(1):47-50. doi: 10.5505/1304.7361.2014.00378. eCollection 2015 Mar. Turk J Emerg Med. 2016. PMID: 27331194 Free PMC article.
-
Screening for thyroid disease in a primary care unit with a thyroid stimulating hormone assay with a low detection limit.BMJ. 1988 Dec 17;297(6663):1586-92. doi: 10.1136/bmj.297.6663.1586. BMJ. 1988. PMID: 3147087 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources