Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Feb;29(2):185-93.

Effect of long-term contact lens wear on corneal endothelial cell morphology and function

Affiliations
  • PMID: 3338878

Effect of long-term contact lens wear on corneal endothelial cell morphology and function

K H Carlson et al. Invest Ophthalmol Vis Sci. 1988 Feb.

Abstract

Anterior segment fluorophotometry (topical) and central endothelial cell photography were performed on 40 long-term (2-23 years) contact lens wearers (four groups of ten each: hard, soft, gas permeable, and gas permeable plus prior lens usage) and 40 non-contact lens wearers of similar ages. Morphologically, the endothelial cells of contact lens wearers showed greater variability in size and shape compared to controls. The mean endothelial cell size in contact lens wearers (307 +/- 35 micron2) was smaller than that of controls (329 +/- 38 micron2, P less than 0.01). There was an increase in the coefficient of variation of cell size of the contact lens group (0.35 +/- 0.06 versus 0.25 +/- 0.04 for controls, P less than 0.0001). The endothelial cell mosaic contained a smaller percentage of hexagonal cells in contact lens wearers (66 +/- 8) compared to controls (71 +/- 7, P less than 0.01). There was a compensatory increase in five-sided cells. Functionally, there was no difference in corneal clarity, central corneal thickness or endothelial permeability to fluorescein (3.78 +/- 0.57 X 10(-4) cm/min versus 3.85 +/- 0.55 X 10(-4) cm/min for controls) between the two groups. Aqueous humor flow was increased 7% in contact lens wearers. We found no correlation between oxygen transmissibility, estimated underlying oxygen tension, or duration of wear of the contact lenses and any morphologic or functional variable. We also found no differences between the four groups of contact lens wearers except that the gas permeable lens wearers had more hexagonal and less pentagonal cells. Long-term contact lens wear induces morphologic changes in the corneal endothelium.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

LinkOut - more resources