Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun;46(6):2722-2728.
doi: 10.1007/s00261-020-02894-9. Epub 2021 Jan 2.

Placental thickness correlates with placenta accreta spectrum (PAS) disorder in women with placenta previa

Affiliations

Placental thickness correlates with placenta accreta spectrum (PAS) disorder in women with placenta previa

Yan Li et al. Abdom Radiol (NY). 2021 Jun.

Abstract

Objective: To evaluate the association of placental thickness with placenta accreta spectrum disorder in placenta previa.

Methods: In this IRB-approved, retrospective study, ultrasound (US) reports were retrospectively queried for keyword previa. US performed closest to mid-gestation were included. Three measurements were performed at the thickest portion of the placenta on longitudinal transabdominal images. Operative reports and surgical pathology were used as the reference standard. Statistical analysis was performed using unpaired T-tests and receiver operating curve (ROC) analysis.

Results: Sixty-five patients with placenta previa were included: 38 with PAS disorder and 27 without PAS disorder, clinically or pathologically. 38/38 (100%) patients of PAS group and 16/27 (59.3%) patients of non-PAS group had history of prior cesarean section. The average placental thickness was 4.3 cm (range 1.8 cm to 7.8 cm) for PAS group and 3.0 cm (range 0.6 cm to 5.3 cm) for non-PAS group (p < 0.001). Placental thickness in patients without PAS disorder and history of prior cesarean section was 3.1 (± 1.1) cm. This was statistically different from patients who had history of prior cesarean section with PAS diagnosis (4.3 cm, P<0.01). Using ROC analysis, a threshold measurement of 4.5 cm leads to sensitivity of 50% and specificity of 96%.

Conclusion: Our results demonstrate that among women with placenta previa, increased placental thickness at lower uterine segment correlates with placenta accreta spectrum disorder. A threshold of 4.5 cm can be useful for screening patients with placenta previa and risks factors for PAS.

Keywords: Low lying placenta; Placenta accreta spectrum; Placenta previa; Placental thickness; Ultrasound.

PubMed Disclaimer

References

Reference

    1. Iyasu S, Saftlas AK, Rowley DL, Koonin LM, Lawson HW, Atrash HK. The epidemiology of placenta previa in the United States, 1979 through 1987. Am J Obstet Gynecol 1993;168: 1424–9. - PubMed
    1. Cresswell JA, Ronsmans C, Calvert C, Filippi V. Prevalence of placenta previa by world region: a systematic review and metaanalysis. Trop Med Int Health 2013;18:712–24. - PubMed
    1. Getahun D, Oyelese Y, Salihu HM, Ananth CV. Previous cesarean delivery and risks of placenta previa and placental abruption. Obstet Gynecol 2006;107:771–8. - PubMed
    1. Ananth CV, Smulian JC, Vintzileos AM. The association of placenta previa with history of cesarean delivery and abortion: a meta-analysis. Am J Obstet Gynecol 1997;177:1071–8. - PubMed
    1. Crane JM, Van den Hof MC, Dodds L, Armson BA, Liston R. Maternal complications with placenta previa. Am J Perinatol 2000;17:101–5. - PubMed

LinkOut - more resources