. 2021 Apr;41(4):1291-1299.
doi: 10.1007/s10792-020-01685-x. Epub 2021 Jan 3.

Evaluation of a novel artificial intelligence-based screening system for diabetic retinopathy in community of China: a real-world study

Affiliations

Evaluation of a novel artificial intelligence-based screening system for diabetic retinopathy in community of China: a real-world study

Shuai Ming et al. Int Ophthalmol. 2021 Apr.

Abstract

Purpose: To evaluate the performance of an AI-based diabetic retinopathy (DR) grading model in real-world community clinical setting.

Methods: Participants with diabetes on record in the chosen community were recruited by health care staffs in a primary clinic of Zhengzhou city, China. Retinal images were prospectively collected during December 2018 and April 2019 based on intent-to-screen principle. A pre-validated AI system based on deep learning algorithm was deployed to screen DR graded according to the International Clinical Diabetic Retinopathy scale. Kappa value of DR severity, the sensitivity, specificity of detecting referable DR (RDR) and any DR were generated based on the standard of the majority manual grading decision of a retina specialist panel.

Results: Of the 193 eligible participants, 173 (89.6%) were readable with at least one eye image. Mean [SD] age was 69.3 (9.0) years old. Total of 321 eyes (83.2%) were graded both by AI and the specialist panel. The κ value in eye image grading was 0.715. The sensitivity, specificity and area under curve for detection of RDR were 84.6% (95% CI: 54.6- 98.1%), 98.0% (95% CI: 94.3-99.6%) and 0.913 (95% CI: 0.797-1.000), respectively. For detection of any DR, the upper indicators were 90.0% (95% CI: 68.3-98.8), 96.6% (95% CI: 92.1-98.9) and 0.933 (95% CI: 0.933-1.000), respectively.

Conclusion: The AI system showed relatively good consistency with ophthalmologist diagnosis in DR grading, high specificity and acceptable sensitivity for identifying RDR and any DR.

Translational relevance: It is feasible to apply AI-based DR screening in community.

Precis: Deployed in community real-world clinic setting, AI-based DR screening system showed high specificity and acceptable sensitivity in identifying RDR and any DR. Good DR diagnostic consistency was found between AI and manual grading. These prospective evidences were essential for regulatory approval.

Keywords: Artificial intelligence; Deep neural network; Diabetic retinopathy; Fundus photography; Rreal-world study.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Wong TY, Sun J, Kawasaki R et al (2018) Guidelines on diabetic eye care: the international council of ophthalmology recommendations for screening, follow-up, referral, and treatment based on resource settings. Ophthalmology 125(10):1608–1622 - DOI
    1. Tan GS, Cheung N, Simo R, Cheung GC, Wong TY (2017) Diabetic macular oedema. Lancet Diabetes Endocrinol 5(2):143–155 - DOI
    1. Gwatidzo SD, Stewart WJ (2017) Diabetes mellitus medication use and catastrophic healthcare expenditure among adults aged 50+ years in China and India: results from the WHO study on global AGEing and adult health (SAGE). Bmc Geriatr 17(1):14 - DOI
    1. Wang L, Gao P, Zhang M et al (2017) Prevalence and ethnic pattern of diabetes and prediabetes in china in 2013. JAMA 317(24):2515–2523 - DOI
    1. Wilson A, Baker R, Thompson J, Grimshaw G (2004) Coverage in screening for diabetic retinopathy according to screening provision: results from a national survey in England and Wales. Diabet Med 21(3):271–278 - DOI

LinkOut - more resources