Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography
- PMID: 33392877
- DOI: 10.1007/s10554-020-02118-7
Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography
Abstract
Despite advances in new CT techniques with radiation dose reduction, there are limited studies describing radiation dose. Describing radiation dose might help to educate physicians on how the benefit of cardiac CT outweighs the potential risk of radiation. The aim of this study was to describe the radiation exposure parameters in newborns and infants and the role of CT scan in providing useful information for optimal surgical planning and management of newborns and infants with complex congenital heart disease. In complex congenital heart disease delineating the anatomy and using the CT images as needed for three-dimensional modelling helps for optimal surgical planning. This single center, retrospective study included 74 infants with CHD (median age 2 months, range 1 day to 9 months) who underwent cardiac CT evaluation from September 2018 to April 2019, using the Siemens Somatom Definition Edge scanner. Total dose length product (DLP) and computed tomographic dose index volume (CTDIvol) were recorded, and the estimated effective radiation dose was calculated using a previously published conversion rate. Median effective radiation dose for the computed tomographic angiography (CTA) was 0.6 mSv. The median DLP was 13 mGycm and median CTDIvol was 3.5 mGy. Cardiac CT can be done with a sub-mSv dose in infants. Cardiac CT completes the standard initial evaluation of neonates and infants with complex CHD, allowing thorough understanding of complex spatial relationships between anatomical and defective structures, and is achievable with minimal radiation exposure.
Keywords: Cardiovascular disease; Computed tomography; Congenital heart disease; Pediatric Imaging; Ultra low dose radiation dose.
References
-
- Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Park JJ (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21:347–365. https://doi.org/10.1007/s10554-004-4015-0 - DOI - PubMed
-
- Mehta R, Lee KJ, Chaturvedi R, Benson L (2008) Complications of pediatric cardiac catheterization: a review in the current era. Catheter Cardiovasc Interv 72:278–285. https://doi.org/10.1002/ccd.21580 - DOI - PubMed
-
- Goo HW (2011) Cardiac MDCT in children: CT technology overview and interpretation. Radiol Clin North Am 49:997–1010. doi: https://doi.org/10.1016/j.rcl.2011.06.001 - DOI - PubMed
-
- Leschka S, Oechslin E, Husmann L et al (2007) Pre- and postoperative evaluation of congenital heart disease in children and adults with 64-section CT. Radiographics 27:829–846. https://doi.org/10.1148/rg.273065713 - DOI - PubMed
-
- Han BK, Lindberg J, Grant K, Schwartz RS, Lesser JR (2011) Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease. Am J Cardiol 107:1541e1546. https://doi.org/10.1016/j.amjcard.2011.01.065 - DOI
MeSH terms