Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2021 Apr;163(4):981-989.
doi: 10.1007/s00701-020-04695-x. Epub 2021 Jan 5.

Clinical evaluation of a real-time inverse planning for Gamma Knife radiosurgery by convex optimization: a prospective comparative trial in a series of vestibular schwannoma patients

Affiliations
Clinical Trial

Clinical evaluation of a real-time inverse planning for Gamma Knife radiosurgery by convex optimization: a prospective comparative trial in a series of vestibular schwannoma patients

Jean Régis et al. Acta Neurochir (Wien). 2021 Apr.

Abstract

Background: Gamma Knife radiosurgery (GKRS) inverse dose planning is currently far from competing effectively with the quality of dose planning developed by experienced experts. A new inverse planning (IP) method based on « efficient convex optimization algorithms » is proposed, providing high-quality dose plans in real time.

Materials and methods: Eighty-six patients treated by GKRS for vestibular schwannomas (VS) were recruited. The treatment plans created by the first author, who has 27 years of experience and has developed and delivered more than 15,000 dose plans, served as reference. A first set of basic constraints determined by default led the IP for an initial real-time dose plan. Additional constraints were interactively proposed by the planner to take other parameters into account. A second optimized plan was then calculated by the IP. The primary endpoint was the Paddick Conformity Index (PCI). The statistical analysis was planned on a non-inferiority trial design. Coverage, selectivity, and gradient indexes, dose at the organ(s) at risk, and 12 Gy isodose line volume were compared.

Results: After a single run of the IP, the PCI was shown to be non-inferior to that of the "expert." For the expert and the IP, respectively, the median coverage index was 0.99 and 0.98, the median selectivity index 0.92 and 0.90, the median gradient index 2.95 and 2.84, the median dose at the modiolus of the cochlea 2.83 Gy and 2.86 Gy, the median number of shots 14.31 and 24.13, and the median beam-on time 46.20 min and 26.77 min. In a few specific cases, advanced tools of the IP were used to generate a second run by adding new constraints either globally (for higher selectivity) or locally, in order to increase or decrease these constraints focally.

Conclusion: These preliminary results showed that this new IP method based on « efficient convex optimization algorithms », called IntuitivePlan®, provided high-quality dose plans in real time with excellent coverage, selectivity, and gradient indexes with optimized beam-on time. If the new IP evaluated here is able to compete in real time with the quality of the treatment plans of an expert with extensive radiosurgical experience, this could allow new planners/radiosurgeons with limited or no experience to immediately provide patients with high-quality GKRS for benign and malignant lesions.

Keywords: Inverse planning; Quality control; Radiosurgery; Stereotactic radiotherapy.

PubMed Disclaimer

References

    1. Leksell L (1951) The stereotaxic method and radiosurgery of the brain. Acta Chirurgica Scandinavia 102:316–319
    1. Leksell L (1968) Cerebral radiosurgery. I. Gammathalanotomy in two cases of intractable pain. Acta Chir Scand 134:585–595 - PubMed
    1. Paddick I (2000) A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. Journal of neurosurgery 93:219–222 - DOI
    1. Regis J (2010) Conformity index for radiosurgery. Neurosurgery 67:E521 - DOI
    1. Wagner TH, Bova FJ, Friedman WA, Buatti JM, Bouchet LG, Meeks SL (2003) A simple and reliable index for scoring rival stereotactic radiosurgery plans. Int J Radiat Oncol Biol Phys 57:1141–1149 - DOI

Publication types

LinkOut - more resources