Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May;75(5):e14003.
doi: 10.1111/ijcp.14003. Epub 2021 Jan 21.

Free triiodothyronine to free thyroxine ratio in the differential diagnosis of thyrotoxicosis and hyperthyroidism: A retrospective study

Affiliations

Free triiodothyronine to free thyroxine ratio in the differential diagnosis of thyrotoxicosis and hyperthyroidism: A retrospective study

Çiğdem Tura Bahadır et al. Int J Clin Pract. 2021 May.

Abstract

Background: Thyroid ultrasound, thyroid scintigraphy and radioactive iodine uptake (RAIU) tests are helpful in the differential diagnosis of thyrotoxicosis and hyperthyroidism. In the setting where these techniques are unavailable or unusable more accessible, and cheaper techniques would be helpful.

Aims: We evaluated the capability of free triiodothyronine to free thyroxine ratio (FT3/FT4) to differentiate Graves' Disease (GD) and destructive thyroiditis (DT).

Methods: In total, 318 patients with GD and 140 patients with DT were included in the study. Patients were assigned to two groups: GD and DT (subacute thyroiditis, painless thyroiditis, postpartum thyroiditis). Serum thyroid-stimulating hormone (TSH), FT4, FT3 levels and FT3/FT4 ratio were evaluated in each group. To obtain the optimal diagnostic cut-off value of FT3, FT4 and FT3/FT4 ratio, ROC curve analysis was performed of all untreated thyrotoxicosis patients.

Results: The optimal FT3/FT4 ratio cut-off value was 2.96, with a sensitivity of 71.7%, the specificity of 88.6%. The area under the ROC curve of the FT3/FT4 ratio regarding the diagnosis of GD was 0.864 (95% CI: 0.830-0.894). The cut-off level of FT3 for GD was determined as 6.6 pg/mL which had a sensitivity of 72.3% and specificity of 68.6% (AUC = 0.771 P < .001). The cut-off level of FT4 for GD was determined as 3.65 ng/dl with a sensitivity of 35.5% and specificity of 83.6% (AUC = 0.615 P < .001). When a high specificity is needed, FT3/FT4 cut-off value increases to 3.63 with 99.3% specificity and 36.5% sensitivity.

Conclusions: FT3/FT4 ratio helps distinguish GD and DT. In cases of situations where RAIU/scintigraphy and TRAb cannot be studied, the FT3/FT4 ratio is a viable diagnostic tool. Cut-off values with higher specificity can be more helpful in differential diagnosis of GD.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Chen X, Zhou Y, Zhou M, Yin Q, Wang S. Diagnostic values of free triiodothyronine and free thyroxine and the ratio of free triiodothyronine to free thyroxine in thyrotoxicosis. Int J Endocrinol. 2018;2018:4836736.
    1. Yoshimura Noh J, Momotani N, Fukada S, Ito K, Miyauchi A, Amino N. Ratio of serum free triiodothyronine to free thyroxine in Graves' hyperthyroidism and thyrotoxicosis caused by painless thyroiditis. Endocr J. 2005;52:537-542.
    1. Amino N, Tada H, Hidaka Y. The spectrum of postpartum thyroid dysfunction: diagnosis, management, and long-term prognosis. Endocrine Pract. 1996;2:406-410.
    1. Alexander EK, Pearce EN, Brent GA, et al. 2017 Guidelines of the American Thyroid Association for the diagnosis and management of thyroid disease during pregnancy and the postpartum. Thyroid. 2017;27:315-389.
    1. Ross DS, Burch HB, Cooper DS, et al. 2016 American Thyroid Association Guidelines for diagnosis and management of hyperthyroidism and other causes of thyrotoxicosis. Thyroid. 2016;26:1343-1421.

LinkOut - more resources