Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Oct 2;60(10):4855-4860.
doi: 10.1093/rheumatology/keaa920.

Crystal deposition measured with dual-energy computed tomography: association with mortality and cardiovascular risks in gout

Affiliations

Crystal deposition measured with dual-energy computed tomography: association with mortality and cardiovascular risks in gout

Anne Marty-Ané et al. Rheumatology (Oxford). .

Abstract

Objectives: To determine whether the volume of monosodium urate (MSU) crystal deposition measured with dual-energy CT (DECT) is predictive of short-term mortality and development of cardiovascular comorbidities and diabetes mellitus.

Methods: Patients with a diagnosis of gout having had baseline DECT scans of their knees and feet to measure the volume of MSU crystal deposition were included to undergo a follow-up visit. Risk factors for mortality and a composite variable (onset of any cardio-metabolic event) were examined using multivariable Cox models.

Results: A total of 128 patients aged 66.1 (14.0) years with gout durations of 11.4 (10.4) years were included; most were naïve of urate lowering therapy (61.7%), with a follow-up visit at 24 (12, 36) months. Baseline serum urate (SU) level was 7.44 (2.29) mg/dl and DECT volume of MSU crystals was 0.2 (0, 0.9) cm3. A total of 14 patients died during follow-up, 6/14 from a cardiovascular cause, and 17 patients presented a new cardio-metabolic comorbidity. Factors associated with mortality risk were baseline DECT volume of MSU crystals [hazard ratio (HR) 1.02, 95% CI: 1.002, 1.03] and baseline SU level (HR 1.04, 95% CI: 1.003, 1.06). DECT volume of MSU crystals was the only factor associated with the onset of cardio-metabolic comorbidities with a HR of 1.014 (95% CI: 1.001, 1.03).

Conclusions: Volume of MSU crystals measured with DECT is a biomarker for the risk of developing new cardio-metabolic diseases and for all-cause mortality.

Keywords: cardiovascular events; dual-energy computed tomography; gout; monosodium urate crystal; mortality.

PubMed Disclaimer

Similar articles

Cited by