Cementless ceramic-on-ceramic total hip arthroplasty in post-traumatic osteoarthritis after acetabular fracture: long-term results
- PMID: 33417021
- DOI: 10.1007/s00402-020-03711-0
Cementless ceramic-on-ceramic total hip arthroplasty in post-traumatic osteoarthritis after acetabular fracture: long-term results
Abstract
Introduction: Total hip arthroplasty (THA) is the standard procedure for post-traumatic osteoarthritis (OA) of the hip after acetabular fracture. However, it is not as simple as a primary THA, challenging the surgeon with anatomical deformity and intra and postoperative complications. In the current literature, there is a lack of studies reporting long-term results. May ceramic-on-ceramic (CoC) bearings provide good clinical and radiological outcomes at a long-term follow-up in patients undergoing THA following acetabular fracture?
Materials and methods: We retrospectively analyzed 68 patients (mean age 47 years [range 22-75)] who underwent cementless modular neck stem THA, all implants CoC bearings (50 previously operatively treated and 18 non-operatively treated) after a specific CT study protocol at our Institute since 2000-2008. Clinical outcomes, prosthetic components' osseointegration, survival rate, and reasons for revision were analyzed. Minimum clinical and radiological follow-up was 10 years.
Results: HHS improved significantly after surgery from 37.6 ± 14.1 to 88.4 ± 11.6. 8 revision surgeries were performed, none for infection: we reported 2 stem aseptic loosening, 2 periprosthetic femoral fractures and 4 modular neck fractures. One implant noise (third-generation ceramic coupling) was described. Cup osseointegration was present (according to Moore the presence of at least 3 radiological criteria defines an effective osseointegration) in 67 patients (98.5%). After a 10 years follow-up, survival rate resulted 88.4%, sensibly higher than most of results reported in the current literature.
Conclusion: The high survival rate may be related to CoC: no osteolysis and no infections were reported. Also acetabular cup loosening incidence was sensibly lower (1.47%) among loosening rate described by other authors. Clinical and radiological outcomes were decent, probably due to modular prosthesis design. Modular necks are a solution which can help achieving a proper functional reconstruction of the hip (offset, center of rotation), but should be avoided in young and overweight patients because of the high risk of fracture. CoC bearings in THAs in post-traumatic OA after acetabular fracture showed good results despite the fact that specific ceramic-related issues have to be considered.
Keywords: Acetabular fracture; Ceramic bearing; Long term; Modular neck; Total hip replacement.
References
-
- Bellabarba C, Berger RA, Bentley CD et al (2001) Cementless acetabular reconstruction after acetabular fracture. J Bone Joint Surg Am 83(6):868–876. https://doi.org/10.2106/00004623-200106000-00008 - DOI - PubMed
-
- Mauffrey C, Hao J, Cuellar DO 3rd et al (2014) The epidemiology and injury patterns of acetabular fractures: are the USA and China comparable? ClinOrthopRelat Res 472:3332–3337. https://doi.org/10.1007/s11999-014-3462-8 - DOI
-
- Makridis KG, Obakponovwe O, Bobak P, Giannoudis PV (2014) Total hip arthroplasty after acetabular fracture: incidence of complications, reoperation rates and functional outcomes: evidence today. J Arthroplasty 29:1983–1990. https://doi.org/10.1016/j.arth.2014.06.001 - DOI - PubMed
-
- Matta JM, Ferguson TA (2005) Total hip replacement after acetabular fracture. Orthopedics 28:959–960 - DOI
-
- Tannast M, Najibi S, Matta JM (2012) Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures. J Bone Joint Surg Am 94:1559–1567. https://doi.org/10.2106/JBJS.K.00444 - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical