Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2021 Aug;35(8):2319-2325.
doi: 10.1053/j.jvca.2020.11.056. Epub 2020 Nov 28.

A Randomized Comparison of Positional Stability: The EZ-Blocker Versus Left-Sided Double-Lumen Endobronchial Tubes in Adult Patients Undergoing Thoracic Surgery

Affiliations
Randomized Controlled Trial

A Randomized Comparison of Positional Stability: The EZ-Blocker Versus Left-Sided Double-Lumen Endobronchial Tubes in Adult Patients Undergoing Thoracic Surgery

Benjamin N Morris et al. J Cardiothorac Vasc Anesth. 2021 Aug.

Abstract

Objective: To assess if there is a difference in the repositioning rate of the EZ-Blocker versus a left-sided double-lumen endobronchial tube (DLT) in patients undergoing thoracic surgery and one-lung ventilation.

Design: Prospective, randomized.

Setting: Single center, university hospital.

Participants: One hundred sixty-three thoracic surgery patients.

Interventions: Patients were randomized to either EZ-Blocker or a DLT.

Measurements and main results: The primary outcome was positional stability of either the EZ-Blocker or a left-sided double-lumen endobronchial tube, defined as the number of repositionings per hour of surgery and one-lung ventilation. Secondary outcomes included an ordinal isolation score from 1 to 3, in which 1 was poor, up to 3, which represented excellent isolation, and a visual analog postoperative sore throat score (0-100) on postoperative days (POD) one and two. Rate of repositionings per hour during one-lung ventilation and surgical manipulation in left-sided cases was similar between the two devices: 0.08 ± 0.15 v 0.11 ± 0.3 (p = 0.72). In right-sided cases, the rate of repositioning was higher in the EZ-Blocker group compared with DLT: 0.38 ± 0.65 v 0.09 ± 0.21 (p = 0.03). Overall, mean isolation scores for the EZ-Blocker versus the DLT were 2.76 v 2.92 (p = 0.04) in left-sided cases and 2.70 v 2.83 (p = 0.22) in right-sided cases. Median sore throat scores for left sided cases were 0 v 5 (p = 0.13) POD one and 0 v 5 (p = 0.006) POD two for the EZ-Blocker and left-sided DLT, respectively.

Conclusion: For right-sided procedures, the positional stability of the EZ-Blocker is inferior to a DLT. In left-sided cases, the rate of repositioning for the EZ-Blocker and DLT are not statistically different.

Keywords: bronchial blocker; double-lumen tube; lung isolation; thoracic anesthesia.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources